In
sta
lla
tion
B
R
S
2
0/2
2
/30
/3
2/4
0
/42
/5
0/5
2
Release
06
0
3/2020
69
EMC interference immunity
Standard
applications
a
a. EN 61131-2, CE, FCC – applies to all devices
Navy
applications
Railway
applications
(trackside) as per
EN 50121-4
Electrostatic discharge
EN 61000-4-2
Contact discharge
±4 kV
±6 kV
±6 kV
EN 61000-4-2
Air discharge
±8 kV
±8 kV
±8 kV
Electromagnetic field
EN 61000-4-3
80 MHz ... 800 MHz
—
—
max. 10 V/m
80 MHz ... 1000 MHz
max. 10 V/m
—
—
800 MHz ... 1000 MHz
—
—
20 V/m
80 MHz ... 2000 MHz
—
max. 10 V/m
—
1.4 GHz ... 2.0 GHz
3 V/m
—
max. 10 V/m
2.0 GHz ... 2.7 GHz
1 V/m
—
5 V/m
5.1 GHz ... 6.0 GHz
—
—
3 V/m
Fast transients (burst) – power supply connection
EN 61000-4-4
±2 kV
±2 kV
±2 kV
Fast transients (burst) – data line
EN 61000-4-4
±1 kV
±1 kV
±2 kV
Voltage surges – power supply connection
EN 61000-4-5
line/ground
±2 kV
±1 kV
±2 kV
EN 61000-4-5
line/line
±1 kV
±0.5 kV
±1 kV
Voltage surges - data line
EN 61000-4-5
line/ground
±1 kV
—
±2 kV
Conducted disturbances
EN 61000-4-6
150 kHz ... 80 MHz
10 V
10 V
10 V
Table 27: EMC interference immunity