42
Installation BRS20/22/30/32/40/42/50/52
Release 06 03/2020
Fasten the wires in the terminal block by tightening the terminal
screws.
Mount the terminal block on the device using screws.
Supply voltage with characteristic value F
Figure 13: (1) DC voltage connection on the device, (2) AC voltage connection on
the device, (3) terminal block mounted on the device (front view),
tightening torque, (4) terminal block mounted on the device (view from
above).
Type of the voltages
that can be
connected
Specification of the supply
voltage
Pin assignment
DC voltage
Rated voltage range DC:
24 V DC ... 48 V DC
Voltage range DC incl.
maximum tolerances:
18 V DC ... 60 V DC
+24 V
Plus terminal of the supply
voltage
0 V
Minus terminal of the supply
voltage
AC voltage
Rated voltage AC:
24 V AC
Voltage range AC incl. maximum tolerances:
18 V AC ... 30 V AC, 50 Hz ... 60 Hz
Table 8:
Supply voltage with characteristic value F: type and specification of the
supply voltage, pin assignment
4.4 lb-in
0.5 Nm
1
2
3
4
24 V AC
24 V AC
+24 V(P1)
+24 V(P2)
0 V 0 V
G
G
RELAY
+24 V(P1)
+24 V(P2)
0V 0V
+
+
-
-
24 V DC ... 48 V DC
24 V DC ... 48 V DC
RELAY