68
In
sta
lla
tion
B
R
S2
0/2
2
/30
/3
2/4
0
/42
/5
0/5
2
Re
lease
06
03/2
020
7.10
Immunity
7.11
Electromagnetic compatibility (EMC)
Note:
Use shielded data cables for gigabit transmission via copper cables. Use shielded data cables for all transmission
rates to meet the requirements according to EN 50121-4 and marine applications.
Immunity
Standard applications
a
a. EN 61131-2, CE, FCC – applies to all devices
Navy applications
Railway applications
(trackside) as per EN 50121-4
IEC 60068-2-6, test Fc
Vibration
5 Hz ... 8.4 Hz with 0.14 in
(3.5 mm) amplitude
2 Hz ... 13.2 Hz with 0.04 in
(1 mm) amplitude
—
8.4 Hz ... 200 Hz with 1 g
13.2 Hz ... 100 Hz
with 0.7 g
—
IEC 60068-2-27, test Ea
Shock
15 g at 11 ms
—
—
Table 25: Immunity
EMC interference emission
Standard applications
a
a. EN 61131-2, CE, FCC – applies to all devices
Navy applications
Railway applications
(trackside) as per EN 50121-4
EN 55032
Class A
—
—
DNV GL Guidelines
—
EMC B
—
FCC 47 CFR Part 15
Class A
—
—
EN 61000-6-4
Fulfilled
—
Fulfilled
Table 26: EMC interference emission