For the supply voltage to be connected, perform the following steps:
Remove the terminal connector from the device.
Connect the wires according to the pin assignment on the device with
the clamps.
Fasten the wires in the terminal block by tightening the terminal
screws.
Mount the terminal block on the device using screws.
Supply voltage with characteristic value U
For the supply voltage to be connected, perform the following steps:
Remove the terminal connector from the device.
Connect the wires according to the pin assignment on the device with
the clamps.
Fasten the wires in the terminal block by tightening the terminal
screws.
Mount the terminal block on the device using screws.
Supply voltage with characteristic value P
Type of the voltages
that can be
connected
Specification of the supply
voltage
Pin assignment
DC voltage
Rated voltage DC:
24 V DC
Voltage range DC incl.
maximum tolerances:
18 V DC ... 30 V DC
+24 V
Plus terminal of the supply
voltage
0 V
Minus terminal of the supply
voltage
Table 9:
Supply voltage with characteristic value U: type and specification of the
supply voltage, pin assignment
Type of the voltages
that can be
connected
Specification of the supply
voltage
Pin assignment
When using PoE:
DC voltage
Rated voltage DC:
48 V DC
+
Plus terminal of the supply
voltage
Voltage range DC incl.
maximum tolerances:
46 V DC ... 57 V DC
-
Minus terminal of the supply
voltage
When using PoE+:
Rated voltage DC:
54 V DC
+
Plus terminal of the supply
voltage
Voltage range DC incl.
maximum tolerances:
52 V DC ... 57 V DC
-
Minus terminal of the supply
voltage
Table 10: Supply voltage with characteristic value P: type and specification of the
supply voltage, pin assignment