32
Frame Control Panel Operation and IP Network Setup
Changing the Multiviewer’s IP Address from the Densité Control Panel
to configure the netmask.
8 Once you have set the network mask and navigated back to the previous menu level,
press the [–] button again.
DEFAULT GW EDIT appears on the control panel’s display.
to configure the gateway.
10 Once you have set the gateway, press the Select button
on the front edge of the
KMV-3901/3911 card
to exit the control menu.
The card restarts. The startup sequence takes approximately five minutes, during which
time the Status LED is blinking orange. Once the startup has completed, the Status LED
should be red (steady) because the card is not connected to the network yet.
11 Connect the KMV-3901/3911 card to your Ethernet switch (see
12 Check the card’s Status LED again, and make sure that it does not indicate an error
condition. See
If the Status LED indicates an error condition, see
out what the other LEDs might be indicating.
13 Verify that the new IP address is effective. See
Verifying the Multiviewer’s IP Address
At this point, it is recommended to back up the new configuration to the controller’s
non-volatile memory by saving a
restore point
.
14 On the Densité frame’s local control panel, press the CONTROLLER button. See
the Densité Frame Control Panel
15 Press the [–] button repeatedly until RESTORE POINTS appears on the display, and then
press the SEL button.
16 Press the [–] button repeatedly until SAVE A CARD appears on the display, and then
press the SEL button.
17 Press the [–] button repeatedly until CARD # N—where N matches the slot number for
the KMV-3901/3911 card whose configuration you wish to save—appears on the
display, and then press the SEL button.
18 If you had to change the Densité controller’s default action from
update settings
to
keep
settings
in order to configure your card’s network settings, then see
Densité Controller’s Restore-Point Settings
, on page 33 again, to revert the default
action to
update settings
.
Notes
• If you do not press any button on the Densité frame local control panel, the
Densité controller will revert to its normal standby mode, and the selected
card's Status LED will revert to its normal operating mode, after 30
seconds.
• If you changed a parameter from the card’s control menu, but have not
applied your change (you did not press the SEL button on the local control
panel), once the 30-second timeout has occurred, the parameters will be
confirmed as if you had pressed the SEL button.
Содержание GRASS VALLEY KMV-3901
Страница 8: ...8 Table of Contents Contact Us 128...
Страница 20: ...20 Installation Mechanical Installation of KMV 3901 3911 Cards in the Densit Frame...
Страница 26: ...26 Multiviewer Cabling Commissioning the Multiviewer...
Страница 38: ...38 Frame Control Panel Operation and IP Network Setup Network Considerations for a Multiviewer Cluster...