101
KMV-3901/KMV-3911
Installation & Service Manual
3 Press the SEL button.
HEAD 1 appears on the control panel’s LCD display.
4 Press the SEL button again.
5 The current resolution for the display that is connected to the multiviewer’s output
head 1 (i.e. through the MV OUT 1 connector) appears on the LCD display.
6 Press the [+] and [–] buttons, to navigate to a suitable output resolution for your
display.
7 Press SEL to apply the value shown on the display.
The selected resolution is applied to the display.
8 Press ESC to return to the previous level in the local control menu.
HEAD 1 appears again on the LCD display.
9 If you wish to change the resolution on the second display (if available), then press the
[–] button.
HEAD 2 appears on the LCD display and you can repeat
above to verify
or configure the resolution of the display that is connected to the multiviewer’s output
head 2 (i.e. through the MV OUT 2 connector).
10 When you are satisfied with the selected output resolution settings, press the Select
button
on the front edge of the KMV-3901/3911 card
to exit the control menu.
Enabling EDID Auto-Detection from the Monitor Wall
Notes
• If you do not press any button on the Densité frame local control panel, the
Densité controller will revert to its normal standby mode, and the selected
card's Status LED will revert to its normal operating mode, after 30
seconds.
• If you changed a parameter from the card’s control menu, but have not
applied your change (you did not press the SEL button on the local control
panel), once the 30-second timeout has occurred, the parameters will be
confirmed as if you had pressed the SEL button.
Notes
• The monitor EDID auto-detection feature is enabled by default in order to
facilitate the initial setup of a Kaleido Software system. Setting an output
head to a specific resolution, from a multiviewer service panel in iControl
(if available), or from a Densité controller’s local control panel disables the
EDID auto-detection for this head (see
Using the Densité Frame Control
).
Содержание GRASS VALLEY KMV-3901
Страница 8: ...8 Table of Contents Contact Us 128...
Страница 20: ...20 Installation Mechanical Installation of KMV 3901 3911 Cards in the Densit Frame...
Страница 26: ...26 Multiviewer Cabling Commissioning the Multiviewer...
Страница 38: ...38 Frame Control Panel Operation and IP Network Setup Network Considerations for a Multiviewer Cluster...