121
KMV-3901/KMV-3911
Step-by-Step Configuration
Limitations
In the current version of the
Kaleido Software
, cascade systems are subject to the following
limitations:
• XAdmin may fail to report the system’s genlock source, reference format, and related
statuses for the second- and third-layer cards (i.e. the ones that are not directly
connected to a monitor wall display). iControl alarm browsers, and filtered system lists
that display alarms in XEdit may also incorrectly report a reference input loss for these
cards.
• Restarting one of the cards may result in a blank monitor wall display. If you restart the
card associated with the third layer of a cascade, then restart the card associated with
the second layer. Once the card associated with the second layer has restarted, then
restart the card associated with the first layer as well.
• An output resolution of 1600 × 1200 is not supported.
• Full screen layouts are not supported.
•
Changing the system name or IP address
of a KMV-3901/3911 multiviewer associated
with a cascade, by using the card’s control panel on the Densité housing frame, or by
using the KMV-3901/3911 control panel in iControl, is not supported. To maintain the
integrity of the underlying cluster configuration, you must use XAdmin, or the monitor
wall menu, to make any such changes. In the advent that such a change was made by
mistake, or that is had to be forced for some reason, you will have to repair the broken
cascade (see
Repairing a Cascade Configuration
on page 118 for details).
•
Changing a display resolution from the monitor wall menu
is not supported and will
break the underlying cluster’s integrity. You must use XEdit to configure the display
resolution (see “Changing Room Display Resolutions” in the Kaleido Software User’s
Manual; see
on page 9). In the advent that such a change was
made by mistake, you will have to repair the broken cascade as follows:
1 Connect to the multiviewer associated with the display whose resolution was
changed by mistake, and open the corresponding room.
• If you wish to
restore the previous resolution
, then set this display to its previous
resolution.
• If you wish to
apply the new resolution
, then change something in the room to
enable the
Save
button (e.g. move a display and then bring it back to its initial
position).
2 On the
File
menu, click
Save
. Alternatively, click the
Save
button on the toolbar.
•
Some changes are not automatically propagated to all members of a cascade.
If you
wish to have the same configuration for every multiviewer in a cascade, then the
following elements must be manually replicated: system calibrations, audio monitoring
output assignment for each RCP user, sources/channels and router configurations,
pointer size configuration.
Note:
After changing the pointer size for a room, on all multiviewers in a
cascade, you must restart every multiviewer, for the change to become
effective across the cascade system.
Содержание GRASS VALLEY KMV-3901
Страница 8: ...8 Table of Contents Contact Us 128...
Страница 20: ...20 Installation Mechanical Installation of KMV 3901 3911 Cards in the Densit Frame...
Страница 26: ...26 Multiviewer Cabling Commissioning the Multiviewer...
Страница 38: ...38 Frame Control Panel Operation and IP Network Setup Network Considerations for a Multiviewer Cluster...