40 / 220 EN
Split type wall mounted air-conditioner / Owner’s Manual
9
Install outdoor unit
9.3 Wiring Connection
1. Loosen the screws and remove E-parts cover from the unit.
2. Connect the cables respectively to the corresponding terminals of the terminal board of the
outdoor unit (see the wiring diagram), and if there are signals connected to the plug, just conduct
butt joint.
3. Ground wire: Remove the grounding screw out of the electric bracket, cover the grounding wire
end onto the grounding screw and screw it into the grounding hole.
4. Fix the cable reliably with fasteners (Pressing board).
5. Put the E-parts cover back in its original place and fasten it with screws.
1
2
L
N
E-parts cover
9.4 Wiring diagram
5
3
N(2)
4
1
L
N
S
N
Lo
L
S
L
N
3
N(2)
1
L
N
Constant speed
To power
To power
To power
To power
To indoor unit
To indoor unit
To indoor unit
To indoor unit
Connector
If there is a connector, connect it directly.