36 / 220 EN
Split type wall mounted air-conditioner / Owner’s Manual
8.7 Fixing the indoor unit
1. Hang the indoor unit on the peg board, and move the unit from left to right to ensure that the hook
is properly positioned in the peg board.
2. Push toward the lower left side and the upper right side of the unit toward the peg board, until the
hook is embedded in the slot and makes a “click” sound.
8.8 Wiring diagram
•
If your air conditioner is provided with power cable, the wiring of the indoor unit is connected in the
factory, there is no need of connection.
•
If the power cable is not provided, connection is needed in accordance with the wiring diagram.
After installation, check:
1. The screws whether have been fixed effectively, and there is no risk of loosening.
2. Connector of display board whether put in the right place and do not touch the terminal board.
3. Control box cover whether cover tightly.
Lo N
S
L
L
N
S
4
1(L)
5
3
2(N)
4
1(L)
5
3
2(N)
Connector
If there is a connector,
connect it directly.
Constant speed
To outdoor unit
To outdoor unit
To outdoor unit
To outdoor unit
Variable speed
8
Install indoor unit
Содержание BEVPA 090
Страница 54: ...Manufactured by Arcelik A S Karaagac Cd No 2 6 34445 Sutluce Beyoglu Istanbul Turkey 19 11 Rev 01 ...
Страница 106: ...19 11 Rev 01 Prodotto da Arcelik A S Karaagac Cd No 2 6 34445 Sutluce Beyoglu Istanbul Turchia ...
Страница 161: ...Fabricado por Arcelik A S Karaagac Cd No 2 6 34445 Sutluce Beyoglu Estambul Turquía 19 11 Rev 01 ...
Страница 217: ...Fabricado por Arcelik A S Karaagac Cd No 2 6 34445 Sutluce Beyoglu Istambul Turquia 19 11 Rev 01 ...
Страница 218: ......
Страница 219: ......
Страница 220: ...www beko com ...