34 / 220 EN
Split type wall mounted air-conditioner / Owner’s Manual
Pipe protection ring
Putty
C
Note:
Usually, the wall hole is 060mm~080mm. Avoid pre-buried power wire and hard
wall when making the hole.
8.4 Route of pipeline
1. Depending on the position of the unit, the piping may be routed sideway from the left or the
right (Fig 1), or vertically from the back (Fig 2) (depending on the pipe length of the indoor unit). In
the case of sideway routing, cut off the outlet cutting stock of the opposite side.
Fig 1
Fig 2
Connecting pipe
drain hose and
cables
Connecting pipe
drain hose and
cables
Outlet material preparation
8.5 Drain pipe connection
1. Remove the mountings and pull the indoor unit pipe out of the housing.
2. Connect the connecting pipe to the indoor unit:
Aim at the pipe center, tighten the Taper nut with fingers, and then tighten the Taper nut with a
torque wrench, and the direction is shown in diagram on the right. The torque used is shown in the
following table.
C
Note:
Carefully check if there is any damage of joints before installation. The joints
shall not be reused, unless after re-flaring the pipe.
8
Install indoor unit
Содержание BEVPA 090
Страница 54: ...Manufactured by Arcelik A S Karaagac Cd No 2 6 34445 Sutluce Beyoglu Istanbul Turkey 19 11 Rev 01 ...
Страница 106: ...19 11 Rev 01 Prodotto da Arcelik A S Karaagac Cd No 2 6 34445 Sutluce Beyoglu Istanbul Turchia ...
Страница 161: ...Fabricado por Arcelik A S Karaagac Cd No 2 6 34445 Sutluce Beyoglu Estambul Turquía 19 11 Rev 01 ...
Страница 217: ...Fabricado por Arcelik A S Karaagac Cd No 2 6 34445 Sutluce Beyoglu Istambul Turquia 19 11 Rev 01 ...
Страница 218: ......
Страница 219: ......
Страница 220: ...www beko com ...