Split type wall mounted air-conditioner / Owner’s Manual
29 / 220 EN
7
Notices for installation
C
Important notices
•
Before installation, please contact with local authorized maintenance center, if unit is
not installed by the authorized maintenance center, the malfunction may not solve,
due to discommodious contact.
•
The air conditioner must be installed by professionals according to the national
wiring rules and this manual.
•
Refrigerant leak test must be made after installation.
•
To move and install air conditioner to another place, please contact our local special
service center.
7.1 Unpacking Inspection
•
Open the box and check air conditioner in area with good ventilation (open the door and window)
and without ignition source. Note: Operators are required to wear anti-static devices.
•
It is necessary to check by professional whether there is refrigerant leakage before opening the box
of outdoor machine; stop installing the air conditioner if leakage is found.
•
The fire prevention equipment and anti-static precautions shall be prepared well before checking.
Then check the refrigerant pipeline to see if there is any collision traces, and whether the outlook is
good.
7.2 Safety Principles for Installing Air Conditioner
•
Fire prevention device shall be prepared before installation.
•
Keep installing site ventilated.(open the door and window)
•
Ignition source, smoking and calling is not allowed to exist in area where R32 refrigerant located.
•
Anti-static precautions in necessary for installing air conditioner, e.g. wear pure cotton clothes and
gloves.
•
Keep leak detector in working state during the installation.
•
If R32 refrigerant leakage occurs during the installation, you shall immediately detect the
concentration in indoor environment until it reaches a safe level. If refrigerant leakage affects the
performance of the air conditioner, please immediately stop the operation, and the air conditioner
must be vacuumed firstly and be returned to the maintenance station for processing.
•
Keep electric appliance, power switch, plug, socket, high temperature heat source and high static
away from the area underneath sidelines of the indoor unit.
•
The air conditioner shall be installed in an accessible location to installation and maintenance,
without obstacles that may block air inlets or outlets of indoor/outdoor units, and shall keep away
from heat source, inflammable or explosive conditions.
Содержание BEVPA 090
Страница 54: ...Manufactured by Arcelik A S Karaagac Cd No 2 6 34445 Sutluce Beyoglu Istanbul Turkey 19 11 Rev 01 ...
Страница 106: ...19 11 Rev 01 Prodotto da Arcelik A S Karaagac Cd No 2 6 34445 Sutluce Beyoglu Istanbul Turchia ...
Страница 161: ...Fabricado por Arcelik A S Karaagac Cd No 2 6 34445 Sutluce Beyoglu Estambul Turquía 19 11 Rev 01 ...
Страница 217: ...Fabricado por Arcelik A S Karaagac Cd No 2 6 34445 Sutluce Beyoglu Istambul Turquia 19 11 Rev 01 ...
Страница 218: ......
Страница 219: ......
Страница 220: ...www beko com ...