Split type wall mounted air-conditioner / Owner’s Manual
35 / 220 EN
Indoor unit pipe
Taper nut
Connecting pipe
Torque wrench
Spanner
Tightening torque table
The size of pipe (mm)
Torque (N·m)
06/06.35
15~25
09/09.52
35~40
012/012.7
45~60
015.88
73~78
019.05
75~80
8.6 Wrap the piping
1. Use the insulation sleeve to wrap the joint part the indoor unit and the connection pipe, and then
use insulating material to pack and seal insulation pipe, to prevent generation of condensate water
on the joint part.
2. Connect the water outlet with drain pipes, and make the connection pipe, cables, and the drain
hose straight.
3. Use plastic cable ties to wrap the connecting pipes, cables and drain hose. Run the pipe sloping
downward.
Connecting pipe drain
hose and cables
Plastic strap
8
Install indoor unit
Содержание BEVPA 090
Страница 54: ...Manufactured by Arcelik A S Karaagac Cd No 2 6 34445 Sutluce Beyoglu Istanbul Turkey 19 11 Rev 01 ...
Страница 106: ...19 11 Rev 01 Prodotto da Arcelik A S Karaagac Cd No 2 6 34445 Sutluce Beyoglu Istanbul Turchia ...
Страница 161: ...Fabricado por Arcelik A S Karaagac Cd No 2 6 34445 Sutluce Beyoglu Estambul Turquía 19 11 Rev 01 ...
Страница 217: ...Fabricado por Arcelik A S Karaagac Cd No 2 6 34445 Sutluce Beyoglu Istambul Turquia 19 11 Rev 01 ...
Страница 218: ......
Страница 219: ......
Страница 220: ...www beko com ...