Connection work - single device
Illustration
Description / explanation
6
G
7
3. Unscrew the counter nut
[6]
from the right cable
gland
[G]
.
4. Remove the plugs
[7]
from the counter nut
[6]
.
6 mm
50 mm
(1.97 in)
(0.23 in)
5. Prepare the connection cable.
X5
G
6
6. Fit the counter nut
[6]
over the connection cable
[X5]
.
7. Insert the connection cable
[X5]
into the right cable
gland
[G]
.
Connection cable
[X5]
8. Connect the connection cable
[X5]
according to
the terminal diagram “4.7 Terminal diagram” on
page 26.
6
G
X5
9. Draw the connection cable
[X5]
taut.
10. Screw the counter nut
[6]
onto the right cable
gland
[G]
.
BEKOMAT
®
33iU / 33iU CO
Original installation and operation manual
36 | 68
Содержание BEKOMAT 33iU
Страница 1: ...EN BEKOMAT 33iU 33iU CO 01 4244 Original installation and operation manual BM33iU BM33iU CO ...
Страница 65: ...16 2 Declaration of Conformity Original installation and operation manual BEKOMAT 33iU 33iU CO 65 68 ...