Exchange work
Illustration
Description / explanation
A
X7
5. Release the control unit
[A]
by pressing the locking
hook
[X7]
.
A
6. Remove the control unit
[A]
.
Power
Alarm
Service
TEST
7. Press the TEST button
[A]
on the control unit and hold
it for at least 5 seconds.
0
The green POWER LED flashes
8. Once the green POWER LED is permanently lit, release
the TEST button.
0
The “Remaining service time” counter (Modbus
address 3103 / 3104) is reset
0
The “Remaining switching cycles” counter (Modbus
address 3105 / 3106) is reset
9. Lay the control unit
[A]
carefully to one side.
Original installation and operation manual
BEKOMAT
®
33iU / 33iU CO
47 | 68
Содержание BEKOMAT 33iU
Страница 1: ...EN BEKOMAT 33iU 33iU CO 01 4244 Original installation and operation manual BM33iU BM33iU CO ...
Страница 65: ...16 2 Declaration of Conformity Original installation and operation manual BEKOMAT 33iU 33iU CO 65 68 ...
Страница 67: ...17 Notes Original installation and operation manual BEKOMAT 33iU 33iU CO 67 68 ...