Exchange work
Illustration
Description / explanation
8
13. If a design shell
[8]
is attached, carefully lift the design
shell
[8]
to the marked positions using a flat head
screwdriver.
14. Carefully remove the design shell
[8]
.
19
20
20
18
14
15. Undo the 4 hexagon socket head cap screws
[20]
of
the condensate collecting container cover
[19]
.
16. Lift the condensate collecting container
[19]
and the
O-ring
[18]
off.
17. Dispose of the old Service-Unit
[12]
and the old
O-ring
[18]
properly. For more information, see “14.
18. Clean the condensate collecting container
[14]
.
18
19
19. Clean the cover sealing faces of the condensate
collecting container cover
[19]
and wipe down using a
clean cloth and without detergent.
20. Insert the new O-ring
[18]
into the condensate
collecting container cover
[19]
as shown.