BAL2185_Grease_lubrication_pump_PICO_with_PICO-troniX1_-tronic_0519EN 10158410
...a product of
© BEKA 201 All
!
9
rights reserved
52
13.
Troubleshooting
Malfunction
Possible cause
Possible remedy
Device does not operate
No power supply
Possibly renew fuse if installed
Electrical line interrupted
Renew electrical line
Device defective
Renew device
Integrated control unit defective
Renew integrated control unit
Device operates, but does not
supply
Air pocket in delivery piston
Ventilate device
Air pocket in reservoir
Ventilate device
Reservoir empty
Fill reservoir
Integrated control unit defective
Renew integrated control unit
Pump element defective
Renew pump element
No grease collar at any lube point
Device does not operate
See malfunction „Device does not
operate“
Lubrication system blocked
See malfunction „Lubricant leakage
at pressure limiting valve“
Lubrication duration (pump operating
time) too short
Extend lubrication duration
T
is shown
he error
Lubrication deficit
See chapter 9.2.14 „Error
Lubrication deficit
“
No grease collar at sever lube
al
points
Supply lines to secondary distributor
burst or leaky
Renew lines
Fittings leaky
Retighten or renew fittings
Device‘s speed reduced
High system pressure
Check lubrication system / lube point
(no damage)
Supply voltage too low
Check supply voltage
Lubricant leakage at pressure
limiting valve
System pressure too high
Check lubrication system
Progressive distributor blocked
Renew affected progressive
distributor
Lubrication system blocked
Repair clogged / firm lube point
Valve spring broken
Renew pressure limiting valve
Level monitoring sends a signal
although the reservoir is filled
Level monitoring defective
Send device to BEKA for repair
Integrated control unit defective
Renew integrated control unit