BAL2185_Grease_lubrication_pump_PICO_with_PICO-troniX1_-tronic_0519EN 10158410
...a product of
© BEKA 201 All
!
9
rights reserved
34
9.
Integrated control unit
Progressive lubrication systems, multi-line lubrication systems and mixed lubrication systems can be controlled with the
control unit PICO-troniX1 or PICO-tronic which is integrated in the device.
The integrated control unit PICO-troniX1 or PICO-tronic operates dependent from the lubrication cycle.
A lubrication cycle consists of the cycle duration and the lubrication duration (pump operating time) which is included in
the cycle duration. Cycle duration means the period from the beginning of a lubrication to the beginning of the next
lubrication (see fig. 35).
Fig. 35:
9.1
PICO-troniX1
The
is determined
for the integrated control unit PICO-troniX1.
cycle duration
time-dependently
The
can be determined
or
.
lubrication duration
time-
revolution-dependently
Functions:
The following functions can be evaluated with the integrated control unit:
·
Level monitoring (only for devices with follow-up piston, see chapter 8.6 „Level monitoring“)
Signal indicators:
The following messages are displayed by the integrated control unit by the red and green LED in the inspection window of
the protective housing (see chapter 13.1 „Signal indicators of the integrated control unit PICO-troniX1"):
·
Operational capability
·
Lubrication in process
·
Reservoir empty (only for devices with follow-up piston)
·
Set number of pump revolutions has not been reached within the monitoring time of revolutions
·
CPU / memory defective
·
Trial lubrication in process
Operational database:
The integrated control unit has an operational database in which the following values are stored:
·
Data of the control unit (type, version, serial number, manufacturing date)
·
Current settings (cycle duration, operational mode of the lubrication duration, lubrication duration, monitoring times)
·
Statistical values (operating hours, operating time of the device, number of the intermediate lubrications, number of
the level errors, number of the revolution errors, number of the overall diagnoses etc.)
·
Date and time of the last diagnosis
The operational mode of the lubrication duration, the setting ranges of the cycle and lubrication
duration and the setting of the monitoring time can be changed at any time using the diagnosis
software
(with the current version available at
).
BEKA-DiSys
www.beka-lube.de
Notice!
Lubrication duraction
Cycle duration
Lubrication cycle