BAL2185_Grease_lubrication_pump_PICO_with_PICO-troniX1_-tronic_0519EN 10158410
...a product of
© BEKA 201 All
!
9
rights reserved
40
9.2.1
Functional description
Fig. 40:
Alubrication starts at initial connection of the integrated control unit.
Each time after the voltage (ignition) is switched on, the red and the green LED glow for approx. 1.5 seconds in the
inspection window of the protective housing and display the operational capability of the integrated control unit.
If the voltage is interrupted (ignition switched off) during a cycle sequence or during the lubrication duration, the data is
stored in the operational database of the integrated control unit. When the voltage (ignition) is switched on again, the
cycle sequence starts where i was interrupted before.
t
When the voltage is switched on, an intermediate lubrication can be triggered at any time by pushing the push-button for
intermediate lubrication. The current data of the cycle is deleted and a new lubrication cycle starts immediately.
Some errors have to be reset after the troubleshooting by pushing the push-button for intermediate lubrication (see
chapter 13. „Troubleshooting“).
Then, the device immediately starts with a lubrication cycle.
8
0,5
Zykluszeit / Cycle time (h) Service
Push-button for
intermediate
lubrication
Inspection window
of the protective
housing
Voltage connection
Hirschmann plug
7-poles
GO070WF
Connection for
additional equipment
Hirschmann plug
7-poles
GO610WF
8
1
16
Service
PICO-tronic
0,5
Schmierzeit
Lubrication time (min)
Zykluszeit / Cycle time (h)
Connect
bushing for
or
the diagnosis software
BEKA-DiSys
LEDs for indicating
the functional state
Grid switch for
setting the
lubrication
duration
Grid switch for
setting the
cycle duration
Adhesive label in inspection
window (example)
Frame of the
inspection window