BAL2185_Grease_lubrication_pump_PICO_with_PICO-troniX1_-tronic_0519EN 10158410
...a product of
© BEKA 201 All
!
9
rights reserved
42
Setting ranges of the time-dependent cycle duration:
·
0,5 to 8 h (16 notches à 0,5 h)
·
1 to 16 min (16 notches à 1 min)
·
2 to 32 min (16 notches à 2 min)
·
2 to 32 h (16 notches à 2 h)
The time-dependent cycle duration can be set (within a setting range) using the right grid switch in the inspection window
of the protective housing (see fig. 40).
9.2.4
Operational mode of pulse-dependent cycle duration
At the operational mode of pulse-dependent cycle duration, the cycle duration is
determined by the number of incoming pulses of a sensor (e.g. proximity switch
at the lubrication pinion, see fig. 42). If the integrated control unit receives no
pulse signal within the adjustable pulse monitoring time of cycle duration
(standard setting 7 days), it displays an error (see chapter 13.2 „Signal indicators
of the integrated control unit PICO-tronic").
When the integrated control unit receives a pulse signal again, the error is
automatically reset and the cycle continues normally.
The sensor can be connected to the integrated control unit at the left Hirschmann
plug-type connection on the protective housing (GO610WF, see fig. 40).
The setting range and the pulse monitoring time of the cycle duration can be changed using the diagnosis software
BEKA-DiSys
www.beka-lube.de
(with the current version available at
).
Fig. 43:
Setting ranges of the pulse-dependent cycle duration:
·
1 to 16 pulses (16 notches à 1 pulse)
·
10 to 160 pulses (16 notches à 10 pulses)
·
20 to 320 pulses (16 notches à 20 pulses)
·
100 to 1600 pulses (16 notches à 100 pulses)
·
500 to 8000 pulses (16 notches à 500 pulses)
The pulse-dependent cycle duration can be set (within a setting range) using the right grid switch in the inspection window
of the protective housing (see fig. 36).
The functions
and
cannot be selected in
S
L
ystem pressure monitoring
ine break monitoring
the operational mode of
.
pulse-dependent cycle duration
Fig. 42:
Proximity
switch
Lubrication
pinion
Notice!
Lubrication duration
Pulse-dependent
cycle duration
Pulse