© BEKA 201
!
9 All rights reserved
BAL2185_Grease_lubrication_pump_PICO_with_PICO-troniX1_-tronic_0519EN 10158410
...a product of
55
13.2
Signal indicators of the integrated control unit PICO-tronic
The functions of the device are displayed via two LEDs (green and red) in the inspection window of the protective housing
(see fig. 40), whereby the red LED always displays an error in the program sequence.
The functions of the device can also be displayed by externally installed signal lamps. However, these have to be ordered
separately (order number on request).
If several errors occur at the same time, they are displayed one after the other with a break of approx. 2 seconds.
Signal indicators
Function
Operable: 1.5 s
ON
ON
OFF
OFF
LED red
LED green
Indication of the operational
capability after switching on the
voltage for the first time
During the whole lubrication
ON
ON
OFF
OFF
LED red
LED green
Sequence of a lubrication
Cycle locked
(is not displayed via the special
function
)
External status signal
Pulse error in operational mode of
pulse-dependent cycle duration
Error
Line break
ON
ON
OFF
OFF
LED red
LED green
1 s 1 s
ON
ON
OFF
OFF
LED red
LED green
1 s
1 s 1 s
1 s
Pulse error in operational mode of
pulse-dependent lubrication duration
ON
ON
OFF
OFF
LED red
LED green
1 s
1 s
ON
ON
OFF
OFF
LED red
LED green
1 s 1 s
1 s 1 s
1 s