8.5.2
Pressure limiting valves with micro switch
The maximum operating pressure in the lubrication system can be electronically monitored by a micro switch which is
attached at the pressure limiting valve.
The micro switch is operated when the pressure in the lubrication system exceeds the value set at the pressure limiting
valve (see fig. 30). The emitted signal of the micro switch can be used customer specifically, e.g. for switching off the
device, or it is evaluated by the integrated control unit PICO-tronic (see chapter 9.2.8 „Function
System pressure
monitoring
“).
Fig. 30:
Technical data of the micro switch
Connection diagram
Supply voltage:
10 to 60 V DC
Current load max.:
I = 1,7A
Contact type:
changeover contact
Temperature range:
-25°C to +85°C
Degree of protection:
IP 67
Connection:
cable 0,5 m long, welded (standard)
Lubricant can leak out at the pressure limiting valve under high pressure (290 bar)!
Wear corresponding personal protective equipment (e.g. safety goggles) and keep out of the direct area of
the pressure limiting valve when there is a malfunction at the device.
Only work at the device when it is in a disconnected and pressureless state!
Lubricant
leakage
black
brown
blue