© BEKA 201
!
9 All rights reserved
BAL2185_Grease_lubrication_pump_PICO_with_PICO-troniX1_-tronic_0519EN 10158410
...a product of
15
7.
Start up
7.1
Lubricants
The device is designed for standard multi-purpose greases up to NLGI cl. 2.
·
Use lubricants with high-pressure additives.
·
Only use lubricants of the same soaping criteria.
·
Do not use any lubricants with solids content (lubricants with solids content on request, e.g. graphite or MoS2)
7.2
Filling with lubricant
·
Fill the lubricant reservoir with clean lubricant at the filling nipple or a filling connection!
·
Observe the machine manufacturer's lubricant details! Only use lubricants according to machine manufacturer's
specifications!
·
Collect leaking lubricant in a suitable reservoir and dispose it professionally!
·
Observe the safety data sheet of the lubricant manufacturer!
·
The lubricant viscosity changes with the operating temperature.
·
Check the level several times in equal intervals during the first hours of operation and refill lubricant, if necessary.
·
Pay attention to utmost cleanness when refilling the reservoir!
By default, you receive the device with a basic filling. The procedure for filling devices with basic
filling can be found in chapter 7.2.2 „Filling of the device“.
If the device has no basic filling, observe the procedure for the initial filling for devices with follow-up
piston which is described in chapter 7.2.1 „Initial filling of devices with follow-up piston“. You can
proceed as described in chapter 7.2.2 „Filling of the device“ for the initial filling of devices with
agitator blade.
Caution!