VOLTAGE WARNING
INDICATOR
1. Red: Energized
2. OFF: De-energized
3. Blinking: overvoltage
LOW SIGNAL
(PRECISION) MODE
ON / OFF BUTTON
TRANSMISSION MODE
INDICATOR
HIGH SIGNAL MODE
Press >2s for Loop mode
MUTE INDICATOR
BATTERY STATUS
LOOP MODE
INDICATOR
RUBBER OVERMOLDED
ENCLOSURE
VOLUME
ADJUSTMENT
BUTTON (+/-)
Figure 2.2e: Overview of AT-6000-TE Transmitter
ON/OFF:
Short press to turn the transmitter on. Long press >2s to turn the transmitter off.
VOLUME ADJUSTMENT BUTTON:
The volume can be changed by short presses on VOLUME UP/
DOWN buttons. The mute and four loudness level are available. The chosen volume level will
be shown on LED display for a short time. If sound is muted, the MUTE LED diode will be on.
The sound pattern is different depending on chosen operating mode, ENERGIZED,
DE-ENERGIZED or LOOP.
VOLTAGE WARNING INDICATOR:
ON for energized circuits 30-600 V AC/DC. OFF for circuits
0-30 V AC/DC. Blinking if overvoltage >650 V AC/DC is detected.
TRANSMISSION MODE INDICATOR:
The LED diodes will blink with different rhythm
depending on chosen operating mode.
Transmitting in HIGH mode – Fast blinking,
Transmitting in LOW mode – Slow blinking,
Transmitting in LOOP mode – Alternating blinking.