EL72x1-0010-MDP742 - Object description and parameterization
8
EL72x1-0010-MDP742 - Object description and
parameterization
Note
EtherCAT XML Device Description
The display matches that of the CoE objects from the EtherCAT XML Device Description.
We recommend downloading the latest XML file from the
download area of the Beckhoff
website
and installing it according to installation instructions.
Note
Parameterization via the CoE list (CAN over EtherCAT)
The terminal is parameterized via the CoE - Online tab (double-click on the respective ob-
ject) or via the Process Data tab (allocation of PDOs).
Please note the following
general CoE information [
}
23]
when using/manipulating the CoE
parameters:
- Keep a
startup list
if components have to be replaced
- Differentiation between online/offline dictionary, existence of current XML description
- use “CoE reload” for resetting changes
Attention
Risk of damage to the device!
We strongly advise not to change settings in the CoE objects while the axis is active, since
this could impair the control.
8.1
Restore object
Index 1011 Restore default parameters
Index (hex) Name
Meaning
Data type
Flags
Default
1011:0
Restore default param-
eters
Restore default parameters
UINT8
RO
0x01 (1
dec
)
1011:01
SubIndex 001
If this object is set to “
0x64616F6C”
in the set value di-
alog, all backup objects are reset to their delivery state.
UINT32
RW
0x00000000
(0
dec
)
8.2
Configuration data
Index 8000 FB Settings
Index (hex) Name
Meaning
Data type
Flags
Default
8000:0
FB Settings
Maximum subindex
UINT8
RO
0x13 (19
dec
)
8000:01
Invert feedback direc-
tion
Inverting the count direction
BOOLEAN
RW
0x00 (0
dec
)
8000:11
Device type
3: OCT (not changeable)
UINT32
RW
0x00000003
(3
dec
)
8000:12
Singleturn bits
Number of
single- and multi-turn-bits [
}
96]
UINT8
RW
0x14 (20
dec
)
8000:13
Multiturn bits
UINT8
RW
0x0C (12
dec
)
EL72x1-0010
165
Version: 2.0
Содержание EL7201-0010
Страница 2: ......
Страница 12: ...Product overview 3 Product overview 3 1 Introduction Fig 8 EL7201 Fig 9 EL7211 EL72x1 0010 12 Version 2 0 ...
Страница 47: ...Commissioning Fig 42 TCP IP setting for the Ethernet port EL72x1 0010 47 Version 2 0 ...
Страница 57: ...Commissioning Fig 61 EtherCAT terminal in the TwinCAT tree EL72x1 0010 57 Version 2 0 ...
Страница 119: ...Commissioning Fig 148 Touch Probe inputs EL72x1 0010 119 Version 2 0 ...
Страница 138: ...Commissioning Fig 168 Process Data tab SM2 EL72x1 0010 default EL72x1 0010 138 Version 2 0 ...
Страница 142: ...Commissioning Fig 171 Process Data tab SM2 EL72x1 0010 default EL72x1 0010 142 Version 2 0 ...