EL72x1-0010-DS402 - Object description and parameterization
Index 6040 Controlword
Index
(hex)
Name
Meaning
Data type
Flags
Default
6040:0
Control-
word
DS402
Controlword [
}
109]
Bit 0: Switch on
Bit 1: Enable voltage
Bit 2: reserved
Bit 3: Enable operation
Bit 4 - 6: reserved
Bit 7: Fault reset
Bit 8 - 15: reserved
UINT16
RO
0x0000
(0
dec
)
Index 6041 Statusword
Index
(hex)
Name
Meaning
Data type
Flags
Default
6041:0
Status-
word
DS402
Statusword [
}
109]
Bit 0: Ready to switch on
Bit 1: Switched on
Bit 2: Operation enabled
Bit 3: Fault
Bit 4: reserved
Bit 5: reserved
Bit 6: Switch on disabled
Bit 7: Warning
Bit 8 + 9: reserved
Bit 10: TxPDOToggle (selection/deselection via
0x60DA [
}
154]
)
Bit 11: Internal limit active
Bit 12: (Target value ignored)
Bit 13 - 15: reserved
UINT16
RO
0x0000
(0
dec
)
Index 6060 Modes of operation
Index
(hex)
Name
Meaning
Data type
Flags
Default
6060:0
Modes
of opera-
tion
permitted values:
0x08: Cyclic synchronous position mode (CSP)
0x09: Cyclic synchronous velocity mode (CSV)
0x0A: Cyclic synchronous torque mode (CST)
0x0B: Cyclic synchronous torque mode with commutation angle (CSTCA)
UINT8
RW
0x00 (0
dec
)
Index 6061 Modes of operation display
Index
(hex)
Name
Meaning
Data type
Flags
Default
6061:0
Modes
of opera-
tion dis-
play
permitted values:
8: Cyclic synchronous position mode (CSP)
9: Cyclic synchronous velocity mode (CSV)
10: Cyclic synchronous torque mode (CST)
11: Cyclic synchronous torque mode with commutation angle (CSTCA)
UINT8
RO
0x00 (0
dec
)
Index 6064 Position actual value
Index
(hex)
Name
Meaning
Data type
Flags
Default
6064:0
Position
actual
value
Position
Unit
: the given value must be multiplied by the corresponding
scaling factor
[
}
100]
UINT32
RO
0x000000
00 (0
dec
)
EL72x1-0010
151
Version: 2.0
Содержание EL7201-0010
Страница 2: ......
Страница 12: ...Product overview 3 Product overview 3 1 Introduction Fig 8 EL7201 Fig 9 EL7211 EL72x1 0010 12 Version 2 0 ...
Страница 47: ...Commissioning Fig 42 TCP IP setting for the Ethernet port EL72x1 0010 47 Version 2 0 ...
Страница 57: ...Commissioning Fig 61 EtherCAT terminal in the TwinCAT tree EL72x1 0010 57 Version 2 0 ...
Страница 119: ...Commissioning Fig 148 Touch Probe inputs EL72x1 0010 119 Version 2 0 ...
Страница 138: ...Commissioning Fig 168 Process Data tab SM2 EL72x1 0010 default EL72x1 0010 138 Version 2 0 ...
Страница 142: ...Commissioning Fig 171 Process Data tab SM2 EL72x1 0010 default EL72x1 0010 142 Version 2 0 ...