Commissioning
EL70x1
174
Version: 4.4
Index 8012 STM Features Ch.1
Index (hex) Name
Meaning
Data type
Flags
Default
8012:19
Select info data 2
Selection "Info data
2"
0
Status word
UINT8
RW
0x04 (4
dec
)
1
Motor voltage coil A
(unit 1 mV)
2
Motor voltage coil B
(unit 1 mV)
3
Motor current coil A
(unit 1 mA)
4
Motor current coil B
(unit 1 mA)
5
Duty-Cycle coil A
(unit 1%)
6
Duty-Cycle coil B
(unit 1%)
7
Current velocity
(value range +/- 10000)
...
reserved
101 Internal temperature of the
driver card
...
reserved
103 Control voltage
104 Motor supply voltage
...
reserved
150 Drive - Status word
151 Drive - State
152 Drive - Position lag (low word)
153 Drive - Position lag (high
word)
...
reserved
255 reserved
8012:30
Invert digital input 1
Inversion of digital input 1
BOOLEAN
RW
0x00 (0
dec
)
8012:31
Invert digital input 2
Inversion of digital input 2
BOOLEAN
RW
0x00 (0
dec
)
8012:32
Function for input 1
Selection of the
function for input 1
0
Normal input
BIT4
RW
0x02 (0
dec
)
1
Hardware Enable
2
Plc cam
3
Auto start
8012:36
Function for input 2
Selection of the
function for input 2
0
Normal input
BIT4
RW
0x02 (0
dec
)
1
Hardware Enable
2
Plc cam
3
Auto start
Index 8013 STM Controller Settings 2 Ch.1
Index (hex) Name
Meaning
Data type
Flags
Default
8013:0
STM Controller Set-
tings 2 Ch.1
Maximum subindex
UINT8
RO
0x08 (8
dec
)
8013:01
Kp factor (velo.)
Kp control factor (proportional component) for the veloc-
ity controller (unit: 0.001)
UINT16
RW
0x03E8
(1000
dec
)
8013:02
Ki factor (velo.)
Ki control factor (integral component) for the velocity con-
troller (unit: 0.001)
UINT16
RW
0x0000 (0
dec
)
8013:03
Inner window (velo.)
Inner window for the I component of the velocity con-
troller (unit: 1%)
UINT8
RW
0x00 (0
dec
)
8013:05
Outer window (velo.)
Outer window for the I component of the velocity con-
troller (unit: 1%)
UINT8
RW
0x00 (0
dec
)
8013:06
Filter cut off frequency
(velo.)
Filter limit frequency of the velocity controller (low-pass,
unit: 1 Hz)
UINT16
RW
0x0000 (0
dec
)
8013:07
Ka factor (velo./pos.)
Ka control factor (acceleration component) for the veloc-
ity controller (unit: 0.001)
UINT16
RW
0x0000 (0
dec
)
8013:08
Kd factor (velo./pos.)
Kd control factor (deceleration component) for the current
controller (unit: 0.001)
UINT16
RW
0x0000 (0
dec
)
Содержание EL7031
Страница 1: ...Documentation EL70x1 Stepper Motor Terminals 4 4 2017 08 18 Version Date...
Страница 2: ......
Страница 6: ...Table of contents EL70x1 6 Version 4 4...
Страница 19: ...Product overview EL70x1 19 Version 4 4 2 3 EL7041 Introduction Fig 10 EL7041 0000 Fig 11 EL7041 0001...
Страница 21: ...Product overview EL70x1 21 Version 4 4 Application example Chapter Commissioning Application example 166...
Страница 48: ...Mounting and wiring EL70x1 48 Version 4 4 Fig 32 Other installation positions example 2...
Страница 96: ...Commissioning EL70x1 96 Version 4 4 Fig 90 Incorrect driver settings for the Ethernet port...
Страница 107: ...Commissioning EL70x1 107 Version 4 4 Fig 109 EtherCAT terminal in the TwinCAT tree left TwinCAT 2 right TwinCAT 3...
Страница 179: ...Commissioning EL70x1 179 Version 4 4 Index 7020 POS Outputs Ch 1...
Страница 203: ...Commissioning EL70x1 203 Version 4 4 Index 7020 POS Outputs Ch 1...