Commissioning
EL70x1
193
Version: 4.4
Index 1C33 SM input parameter
Index (hex) Name
Meaning
Data type
Flags
Default
1C33:0
SM input parameter
Synchronization parameters for the inputs
UINT8
RO
0x20 (32
dec
)
1C33:01
Sync mode
Current synchronization mode:
• 0: Free Run
• 1: Synchron with SM 3 Event (no outputs
available)
• 2: DC - Synchron with SYNC0 Event
• 3: DC - Synchron with SYNC1 Event
• 34: Synchron with SM 2 Event (outputs available)
UINT16
RW
0x0022 (34
dec
)
1C33:02
Cycle time
as
0x1C32:02 [
}
192]
UINT32
RW
0x000F4240
(1000000
dec
)
1C33:03
Shift time
Time between SYNC0 event and reading of the inputs (in
ns, only DC mode)
UINT32
RO
0x00000000
(0
dec
)
1C33:04
Sync modes sup-
ported
Supported synchronization modes:
• Bit 0: free run is supported
• Bit 1: Synchronous with SM 2 Event is supported
(outputs available)
• Bit 1: Synchronous with SM 3 Event is supported
(no outputs available)
• Bit 2-3 = 01: DC mode is supported
• Bit 4-5 = 01: input shift through local event
(outputs available)
• Bit 4-5 = 10: input shift with SYNC1 event (no
outputs available)
• Bit 14 = 1: dynamic times (measurement through
writing of
0x1C32:08 [
}
192]
or
0x1C33:08 [
}
193]
)
UINT16
RO
0xC007
(49159
dec
)
1C33:05
Minimum cycle time
as
0x1C32:05 [
}
192]
UINT32
RO
0x000249F0
(150000
dec
)
1C33:06
Calc and copy time
Time between reading of the inputs and availability of the
inputs for the master (in ns, only DC mode)
UINT32
RO
0x00000000
(0
dec
)
1C33:07
Minimum delay time
UINT32
RO
0x00000000
(0
dec
)
1C33:08
Command
as
0x1C32:08 [
}
192]
UINT16
RW
0x0000 (0
dec
)
1C33:09
Maximum Delay time
Time between SYNC1 event and reading of the inputs (in
ns, only DC mode)
UINT32
RO
0x00000000
(0
dec
)
1C33:0B
SM event missed
counter
as
0x1C32:11 [
}
192]
UINT16
RO
0x0000 (0
dec
)
1C33:0C
Cycle exceeded
counter
as
0x1C32:12 [
}
192]
UINT16
RO
0x0000 (0
dec
)
1C33:0D
Shift too short counter as
0x1C32:13 [
}
192]
UINT16
RO
0x0000 (0
dec
)
1C33:20
Sync error
as
0x1C32:32 [
}
192]
BOOLEAN
RO
0x00 (0
dec
)
Index F000 Modular device profile
Index (hex) Name
Meaning
Data type
Flags
Default
F000:0
Modular device profile General information for the modular device profile
UINT8
RO
0x02 (2
dec
)
F000:01
Module index dis-
tance
Index distance of the objects of the individual channels
UINT16
RO
0x0010 (16
dec
)
F000:02
Maximum number of
modules
Number of channels
UINT16
RO
0x0003 (3
dec
)
Index F008 Code word
Index (hex) Name
Meaning
Data type
Flags
Default
F008:0
Code word
see
note [
}
32]
!
UINT32
RW
0x00000000
(0
dec
)
Содержание EL7031
Страница 1: ...Documentation EL70x1 Stepper Motor Terminals 4 4 2017 08 18 Version Date...
Страница 2: ......
Страница 6: ...Table of contents EL70x1 6 Version 4 4...
Страница 19: ...Product overview EL70x1 19 Version 4 4 2 3 EL7041 Introduction Fig 10 EL7041 0000 Fig 11 EL7041 0001...
Страница 21: ...Product overview EL70x1 21 Version 4 4 Application example Chapter Commissioning Application example 166...
Страница 48: ...Mounting and wiring EL70x1 48 Version 4 4 Fig 32 Other installation positions example 2...
Страница 96: ...Commissioning EL70x1 96 Version 4 4 Fig 90 Incorrect driver settings for the Ethernet port...
Страница 107: ...Commissioning EL70x1 107 Version 4 4 Fig 109 EtherCAT terminal in the TwinCAT tree left TwinCAT 2 right TwinCAT 3...
Страница 179: ...Commissioning EL70x1 179 Version 4 4 Index 7020 POS Outputs Ch 1...
Страница 203: ...Commissioning EL70x1 203 Version 4 4 Index 7020 POS Outputs Ch 1...