Operation
EK1960
76
Version: 1.3.1
NOTE
Power supply during download
Make sure that the TwinSAFE Logic is not switched off during the download. This can lead to unexpected
behavior or permanently disable the TwinSAFE Logic.
WARNING
Execution of the safety application
During a login or download of a safety application, the execution of the current project is stopped on the
TwinSAFE Logic.
Fig. 80: Download Project Data – The Login dialog
In the
Download Project Data
dialog specify the user name, the serial number of the EL6910/EJ6910 or the
logic component onto which the project is to be loaded, and the user password. The default user name is
Administrator,
the default-password is
TwinSAFE
. Use the
Next
button to move to the next dialog.
Fig. 81: Download Project Data – The Select Project Data dialog
In the
Select Project Data
dialog select
Complete Project Data
to load the whole project onto the EL6910/
EJ6910 or the logic component. Use the
Next
button to move to the next dialog.