![Beckhoff AX8911 Скачать руководство пользователя страница 52](http://html1.mh-extra.com/html/beckhoff/ax8911/ax8911_documentation_2719317052.webp)
Safe Motion functions
AX8911
52
Version: 1.2.0
Fig. 25: SAR, SMA with FB Limit
7.10
Safety function SDI
The safe signals SDI_n (Safe Direction Negative – axis rotates in the negative direction) and SDI_p (Safe
Direction Positive – axis rotates in the positive direction) are provided to the user as safe Boolean inputs and
can be used directly in the safety application (see
).
7.11
Safety function SLI
The safety function SLI (Safe Limited Increment) is implemented via the function block FB SLI. The current
value of the connected variable EncoderPosition is latched on a rising edge at the input SLI. The output
SLIActive remains set as long as the input SLI is set and the position lies within the parameterized limits.
This safe output signal can be used in the following safety application.
Fig. 26: SLI with FB SLI