![Beckhoff AX8911 Скачать руководство пользователя страница 33](http://html1.mh-extra.com/html/beckhoff/ax8911/ax8911_documentation_2719317033.webp)
Use of the STO function
AX8911
33
Version: 1.2.0
Fig. 16: Default TwinSAFE logic program for AX8911
NOTE
Brake control
The brake is only controlled via the AX8000 in the delivery state in accordance with the parameterization in
the TC3 Drive Manager 2. The brake output is generally enabled in the AX8911 firmware. The default Twin-
SAFE logic program shown above is implemented accordingly on the AX8911; however, the brake outputs
1 and 2 currently have no effect. The
Brake (over FSoE)
signal does not exist in the TwinSAFE connection.
WARNING
STO switch-off paths
There are 4 STO switch-off paths per axis within the logic (STO output A - D). If the safety logic on the
AX8911 is replaced by a user-specific project, all 4 switch-off paths must be set for each axis.
Also see about this
2
Содержание AX8911
Страница 2: ......
Страница 25: ...Operation AX8911 25 Version 1 2 0 Fig 6 Projects with outputs to the AX8911...
Страница 63: ...Appendix AX8911 63 Version 1 2 0 12 2 Certificates...
Страница 64: ...Appendix AX8911 64 Version 1 2 0...