![Beckhoff AX8911 Скачать руководство пользователя страница 21](http://html1.mh-extra.com/html/beckhoff/ax8911/ax8911_documentation_2719317021.webp)
Operation
AX8911
21
Version: 1.2.0
NOTE
Wiring
Wires with ferrules with plastic collars must be used when using the STO safety function via the STO inputs
on X15 and X25.
5.2.4.2
Setting the TwinSAFE address
If a TwinSAFE connection is used instead of the digital inputs for the implementation of the safety functions
or selection of the STO function, a safety address must be set on the axis module.
This setting is made with the integrated DIP switch on the AX8000 axis module, which is located under the
cover between the X15 and X25 inputs or, in the case of 1-axis modules, to the left of X15.
AX81xx-xxxx 1-axis module
AX82xx-xxxx 2-axis module
DIP switch
Address
1
2
3
4
5
6
7
8
9
10
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
1
OFF
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
2
ON
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
3
OFF
OFF
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
4
ON
OFF
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
5
OFF
ON
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
6
ON
ON
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
7
...
...
...
...
...
...
...
...
...
...
...
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
1023
WARNING
TwinSAFE address
Each TwinSAFE address may only be used once within a network / a configuration!
The address 0 is not a valid TwinSAFE address!
Содержание AX8911
Страница 2: ......
Страница 25: ...Operation AX8911 25 Version 1 2 0 Fig 6 Projects with outputs to the AX8911...
Страница 63: ...Appendix AX8911 63 Version 1 2 0 12 2 Certificates...
Страница 64: ...Appendix AX8911 64 Version 1 2 0...