![Beckhoff AX8911 Скачать руководство пользователя страница 40](http://html1.mh-extra.com/html/beckhoff/ax8911/ax8911_documentation_2719317040.webp)
Safe Motion functions
AX8911
40
Version: 1.2.0
Offset
Name
Data
type
Group
Description
24.0
Encoder Axis 2 Voltage Underrange BOOL
Standard
True
: Encoder undervoltage (OCT or Endat Axis 2)
False
: No error
(Link to output signal 10.4)
24.1
Encoder Axis 2 Voltage Overrange
BOOL
Standard
True
: Encoder overvoltage (OCT or Endat Axis 2)
False
: No error
(Link to output signal 10.5)
24.2
Encoder Axis 2 Module Fault
BOOL
Standard
True
: Fault in encoder voltage
False
: No error
24.3
Encoder Axis 2 Enable
BOOL
Standard
True:
Encoder Axis2 is switched on according to AX8000
False
: Encoder Axis2 is switched off according to AX8000
(Link to output signal 10.6)
24.4-25.7
Reserve (0)
-
26-27
Encoder Voltage Axis 2
UINT16 Standard
Analog value of encoder voltage (OCT or Endat axis 2) in mV
28-29
Reserve (0)
-
30-31
Electrical angle Axis 2
UINT16 Standard
Electrical angle (2π per pole)
32-33
Current I
Q
Axis 2
INT16
Standard
Analog value of current I
Q
(Axis 2),
torque-forming current
34-35
Current I
D
Axis 2
INT16
Standard
Analog value of current I
D
(Axis 2),
field-forming current
36-37
Current phase U Axis 2
INT16
Standard
Analog value of phase current U (Axis 2)
38-39
Current phase V Axis 2
INT16
Standard
Analog value of phase current V (Axis 2)
40-41
Current phase W Axis 2
INT16
Standard
Analog value of phase current W (Axis 2)
42.0
Safety control Axis 2: Run
BOOL
Standard
Run signal for Axis 2 from AX8000 control word
42.1
Safety control Axis 2: ErrAck
BOOL
Standard
Error Acknowledge signal for Axis 2 from AX8000 control word
(Link to output signal 1.2, 1.7, 2.3, 8.0, 22.0, 26.0)
42.2-43.7
Safety Control Axis 2 reserve
-
44-45
Brake current Axis 1 C1 (mA)
INT16
Standard
Analog value for brake current (Axis 1, Port X13.B+ and B-) mea-
sured by µC1 in mA
46-47
Brake current Axis 1 C2 (mA)
INT16
Standard
Analog value for brake current (Axis 1, Port X13.B+ and B-) mea-
sured by µC2 in mA
48-49
Reference Voltage Brake Currents
C1 (mV)
UINT16 Standard
Analog value of brake reference voltage measured by µC1 in mV
50-51
Reference Voltage Brake Currents
C2 (mV)
UINT16 Standard
Analog value of brake reference voltage measured by µC2 in mV
52-53
Brake current Axis 2 C1 (mA)
INT16
Standard
Analog value for brake current (Axis 2, Port X23.B+ and B-) mea-
sured by µC1 in mA
54-55
Brake current Axis 2 C2 (mA)
INT16
Standard
Analog value for brake current (Axis 2, Port X23.B+ and B-) mea-
sured by µC2 in mA
The following input signals are now available in the Safe Motion variant AX8xxx-x2xx
56.0
Primary SAFEDRIVEFEEDBACK
Axis 1 Module Fault
BOOL
Safety
True
: Error detected in the encoder (Axis 1 Port X13.T+ and T-)
False:
No error
(Link to output signal 6.7)
56.1
Primary SAFEDRIVEFEEDBACK
Axis 1 Encoder Ready
BOOL
Standard
True
: Encoder (Axis 1 Port X13.T+ and T-) is ready for operation
according to AX8000
False
: Encoder (Axis 1 Port X13.T+ and T-) is not ready for oper-
ation according to AX8000
(Link to output signal 12.0)
56.2
Primary SAFEDRIVEFEEDBACK
Axis 1 Position Valid
BOOL
Safety
True
: Encoder (Axis 1 Port X13.T+ and T-) process data are
valid
False
: Encoder (Axis 1 Port X13.T+ and T-) process data are
NOT
valid or are frozen
56.3
Primary SAFEDRIVEFEEDBACK
Axis 1 SDI_p
BOOL
Safety
True
: Encoder (Axis 1 Port X13.T+ and T-) rotates in the positive
direction
False:
Encoder (Axis 1 Port X13.T+ and T-) does not rotate in
the positive direction
56.4
Primary SAFEDRIVEFEEDBACK
Axis 1 SDI_n
BOOL
Safety
True
: Encoder (Axis 1 Port X13.T+ and T-) rotates in the nega-
tive direction
False
: Encoder (Axis 1 Port X13.T+ and T-) does not rotate in
the negative direction
56.5-57.7
Reserve (0)
-
58-61
Reserve (0)
-
62-65
Primary SAFEDRIVEFEEDBACK
Axis 1 Standard Multiturn Position
UINT32 Standard
Analog value of multi-turn position
(Axis 1, Port X13.T+ and T-) (unit: increments)
66-69
Primary SAFEDRIVEFEEDBACK
Axis 1 Safety Singleturn Position
UINT32 Safety
Analog value of single-turn position
(Axis 1, Port X13.T+ and T-) (unit: increments)