Safe Motion functions
AX8911
39
Version: 1.2.0
Offset
Name
Data
type
Group
Description
0.0
SAFEOUT STO Module Axis 1
Module Fault
BOOL
Safety
True
: Error detected in the switch-off paths (STO Axis 1)
False
: No error
(Link to output signal 6.1)
0.1
SAFEOUT STO Module Axis 2
Module Fault
BOOL
Safety
True
: Error detected in the switch-off paths (STO Axis 2)
False
: No error
(Link to output signal 10.1)
0.2
SAFEOUT BRAKE Module Axis 1
Module Fault
BOOL
Safety
True
: Error detected in the brake control (Axis 1)
False
: No error
(Link to output signal 6.3)
0.3
SAFEOUT BRAKE Module Axis 1
Active
BOOL
Standard
True
: Brake Axis 1 is vented according to AX8000
False
: Brake is applied according to AX8000.
0.4
SAFEOUT BRAKE Module Axis 2
Module Fault
BOOL
Safety
True
: Error detected in the brake control (Axis 2)
False
: No error
(Link to output signal 10.3)
0.5
SAFEOUT BRAKE Module Axis 2
Active
BOOL
Standard
True
: Brake Axis 2 is vented according to AX8000
False
: Brake is applied according to AX8000.
0.6
SAFEIN Module Axis 1 Channel 1
BOOL
Safety
True
: 24 V on Port X15.1
False
: 0 V on Port X15.1
0.7
SAFEIN Module Axis 1 Channel 2
BOOL
Safety
True
: 24 V on Port X15.2
False
: 0 V on Port X15.2
1.0
SAFEIN Module Axis 1 Module
Fault
BOOL
Safety
True
: Error detected in the safe inputs (Axis 1)
False
: No error
(Link to output signal 6.2)
1.1
SAFEIN Module Axis 2 Channel 1
BOOL
Safety
True
: 24 V on Port X25.1
False
: 0 V on Port X25.1
1.2
SAFEIN Module Axis 2 Channel 2
BOOL
Safety
True:
24 V on Port X25.2
False
: 0 V on Port X25.2
1.3
SAFEIN Module Axis 2 Module
Fault
BOOL
Safety
True
: Error detected in the safe inputs (Axis 2)
False
: No error
(Link to output signal 10.2)
1.4
SAFEOUT STO Module Axis 1 STO
Not Active
BOOL
Standard
Inverted signal from output signal "STO NOT Active" (Axis 1)
1.5
SAFEOUT STO Module Axis 2 STO
Not Active (negated)
BOOL
Standard
Inverted signal from output signal "STO NOT Active" (Axis 2)
1.6-1.7
Reserve (0)
-
2.0
Encoder Axis 1 Voltage Underrange BOOL
Standard
True
: Encoder undervoltage (OCT or Endat Axis 1)
False
: No error
(Link to output signal 6.4)
2.1
Encoder Axis 1 Voltage Overrange
BOOL
Standard
True
: Encoder overvoltage (OCT or Endat Axis 1)
False
: No error
(Link to output signal 6.5)
2.2
Encoder Axis 1 Module Fault
BOOL
Standard
True
: Fault in encoder voltage
False:
No error
2.3
Encoder Axis 1 Enable
BOOL
Standard
True
: Encoder Axis1 is switched on according to AX8000.
False
: Encoder Axis1 is switched off according to AX8000.
(Link to output signal 6.6)
2.4-3.7
Reserve (0)
-
4-5
Encoder Voltage Axis 1
UINT16 Standard
Analog value of encoder voltage (OCT or Endat axis 1) in mV
6-9
Reserve (0)
-
10-11
Electrical angle Axis 1
UINT16 Standard
Electrical angle (2π per pole)
12-13
Current I
Q
Axis 1
INT16
Standard
Analog value of current I
Q
(Axis 1),
torque-forming current
14-15
Current I
D
Axis 1
INT16
Standard
Analog value of current I
D
(Axis 1),
field-forming current
16-17
Current phase U Axis 1
INT16
Standard
Analog value of phase current U (Axis 1)
18-19
Current phase V Axis 1
INT16
Standard
Analog value of phase current V (Axis 1)
20-21
Current phase W Axis 1
INT16
Standard
Analog value of phase current W (Axis 1)
22.0
Safety control Axis 1: Run
BOOL
Standard
Run signal for Axis 1 from AX8000 control word
22.1
Safety control Axis 1: ErrAck
BOOL
Standard
Error Acknowledge signal for Axis 1 from AX8000 control word
(Link to output signal 0.4, 1.5, 2.2, 4.0, 14.0, 18.0)
22.2-23.7
Safety Control Axis 1 reserve
-