Safe Motion functions
AX8911
51
Version: 1.2.0
7.8
Safety function SLS, SSM, SSR, SMS
The safety functions SLS (Safe Limited Speed), SSM (Safe Speed Monitor), SSR (Safe Speed Range) and
SMS (Safe Maximum Speed) can be implemented via an FB Limit. The safe speed is connected to the FB
Limit and the minimum and maximum speeds parameterized. If the current speed (maximum speed in the
last logic cycle) lies within the defined limits, the output
InLimit
of the FB Limit is set. This signal can then be
used for the further processing in the safety application. Here, for example, it is wired to an FB EStop, which
switches the output off as soon as the speed exceeds or falls below the limit. The restart lock is implemented
via a Restart, which is connected to a safe signal.
Fig. 24: SLS, SSM, SSR, SMS with FB Limit
7.9
Safety function SAR, SMA
The safety functions SAR (Safe Acceleration Range) and SMA (Safe Maximum Acceleration) can be
implemented via an FB Limit. The safe acceleration is connected to the FB Limit and the minimum and
maximum acceleration values parameterized. If the current acceleration (maximum acceleration in the last
logic cycle) lies within the defined limits, the output InLimit of the FB Limit is set. This signal can then be
used for the further processing in the safety application. Here, for example, it is wired to an FB EStop, which
switches the output off as soon as the acceleration exceeds or falls below the limit. The restart lock is
implemented via a Restart, which is connected to a safe signal.