Initializing and Setting Up the Routers
112768 Rev. B
3-17
2.
Enter the cluster port number for the attachment (backplane segment)
you want to set: interface 1, 2, 3, or 4.
For the results shown in Figure 3-10, 1 is entered at the prompt.
The following prompt is displayed:
Enter new backplane attachment (13 = disconnect, 1 to 12):
3.
Enter the slot number of the attachment (backplane segment) you want
to change.
For the results shown in Figure 3-10, 8 is entered at the prompt.
The connection table is displayed to show the change.
If you want to disconnect (segment) an interface from the backplane, enter 13.
Figure 3-10.
Connection Table Changes
4.
Repeat steps 2 and 3 for each interface you want to attach to the
backplane.
Cluster Backplane
Port Status Attachments MAC Address
-------- -------- ------------- -----------------
1 Connected 8 00-00-00-00-00-00
2 Segmented None 00-00-00-00-00-00
3 Segmented None 00-00-00-00-00-00
4 Segmented None 00-00-00-00-00-00
Changing backplane attachments...