Parameter
V-Controller (BUS 6 VC)
59
Baumüller Nürnberg Electronic GmbH & Co. KG
5.03047.01
7.9
Data Set Management
Function
Data sets can be loaded from EPROM, changed and saved. 4 data sets can be managed at every time.
!
After switching on (booting)
Directly after switching on the operating voltage supply the DSM (data set management) automati-
cally loads the boot data set (data set 0) into the drive's user memory.
After successful execution of this command the DSM stops in
state 0003:
STAND_BY (P191)
message 0000:
no error (P192).
If no boot data set has been created yet, the DSM is in
state 000B:
STAND_BY with error (P191)
message 0002:
data set not available (P192).
In addition to the drive managers state changes to „F“ fault and parameter M error code (P124) dis-
plays the error code 0902.
!
Creating and updating a boot data set
This measure sets all DSM parameters to value 0. This also refers to data set name (P193) and data
set version (P194), which in this state represent the boot data set.
It must now be set via the command 5: write data set into EEPROM (P190) how the boot data set is
to be created for the first time in EEPROM or how an existing boot data set is to be updated.
1)
Only in the case of message 0000: no error (P192) and DSM state 0003: STAND_BY is the data set
been written correctly.
1)
The counter „DS program cycle“ (P197) is increased by 1.
!
Creating and updating other data sets
The procedure is identical to that of creating and updating a boot data set except that the parameter
data set name (P193) can now be selected from numbers 1 to 2.
Data sets can be transmitted to the working memory with command 6: read data set from EEPROM
(P190).
Only in the case of DSM message 0000: no error (P192) and DSM state 0003: STAND_BY has the
data set been written correctly.
NOTE
Prior to any new action the DSM (data set management) must first be reset by the command 0:
Reset (P190)
Содержание BUS 6 VC
Страница 1: ...E 5 03047 01 Manual V Controller BUS 6 VC Specification Digital Control BUC ...
Страница 4: ...Dokument Nr Document No 5 04058 01 Baumüller Nürnberg GmbH ...
Страница 8: ...6 V Controller BUS 6 VC 5 03047 01 Baumüller Nürnberg Electronic GmbH Co KG ...
Страница 14: ...Technical Data 12 V Controller BUS 6 VC 5 03047 01 Baumüller Nürnberg Electronic GmbH Co KG ...
Страница 16: ...Transportation Unpacking 14 V Controller BUS 6 VC 5 03047 01 Baumüller Nürnberg Electronic GmbH Co KG ...
Страница 92: ...Parameter 90 V Controller BUS 6 VC 5 03047 01 Baumüller Nürnberg Electronic GmbH Co KG ...
Страница 108: ...Appendix 106 V Controller BUS 6 VC 5 03047 01 Baumüller Nürnberg Electronic GmbH Co KG ...
Страница 109: ......