Parameter
64
V-Controller (BUS 6 VC)
5.03047.01
Baumüller Nürnberg Electronic GmbH & Co. KG
Change data set via P196
The time in which this procedure is carried out will differ according to the loading of the mi-
croprocessor.
P198
DSM
key
NOTE
This parameter can be used to change data sets via digital inputs. A change over must not
be executed if controller is enabled!
Bit no.
Meaning
0
0: Data set 3 is write-protected
1: Data set 3 is write-enabled
(only after input of password 1)
1
0: The article no. of all data sets is write-protected
1: The article no. of all data sets is write-enabled
(only after input of password 2)
2 ... 15
reserved