Maintenance
94
V-Controller (BUS 6 VC)
5.03047.01
Baumüller Nürnberg Electronic GmbH & Co. KG
!
Power Supply Function Module (Error ID 05xx)
!
Data Set Management Function Module (Error ID 09xx)
!
Operating System Function Module (Error ID 0Bxx)
*)
Errors cannot be acknowledged.
Error ID
Error Text
Meaning
Error reaction
Remedy
0503
hex
Fault
PLL
Mains jitter has exceeded the
mains jitter limit
Inhibit pulses im-
mediately
Check mains voltage
X1:8/9/10 at BUC Gerät.
Reset error memory.
Error ID
Error Text
Meaning
Error reaction
Remedy
0901
hex
EEPROM copy error
A data difference was determined at
copying of the EEPROM during initial-
ization of data set management
Inhibit pulses immedi-
ately
This error cannot
be acknowledged
and you can only
eliminate it by
switching the elec-
tronics supply off
and on again. If the
error occurs repeat-
edly, this indicates
that there is a de-
fect in the control-
ler hardware.
0902
hex
Missing boot data set
There is no boot data set (DS no. 0)
in the EEPROM
Inhibit pulses immedi-
ately
You must create
the boot data set in
RAM and then save
it to the EEPROM.
0903
hex
Checksum error in boot
data set
At checking of the boot data set, the
system calculated a different check-
sum than the one that was expected,
i.e. a boot data set is present but it is
invalid due to data corruption.
Inhibit pulses immedi-
ately
You must create
the boot data set in
RAM and then save
it to the EEPROM.
Error ID
Error Text
Meaning
Error reaction
Remedy
0B01
hex
Main program comput-
ing time exceeded
Inhibit pulses immedi-
ately
P160 selection = 0,
P169 value = 0,
Store the data set
again and acknowl-
edge the error. If
necessary deacti-
vate functions not
needed for instance
digital and analog
I/O´s by parameter-
ization
0B02
hex
Task computing time
exceeded
Inhibit pulses immedi-
ately
0B03
hex
Sync. IR computing
time exceeded
Inhibit pulses immedi-
ately
0B04
hex
*
DSP computing time
exceeded
Inhibit pulses immedi-
ately
Содержание BUS 6 VC
Страница 1: ...E 5 03047 01 Manual V Controller BUS 6 VC Specification Digital Control BUC ...
Страница 4: ...Dokument Nr Document No 5 04058 01 Baumüller Nürnberg GmbH ...
Страница 8: ...6 V Controller BUS 6 VC 5 03047 01 Baumüller Nürnberg Electronic GmbH Co KG ...
Страница 14: ...Technical Data 12 V Controller BUS 6 VC 5 03047 01 Baumüller Nürnberg Electronic GmbH Co KG ...
Страница 16: ...Transportation Unpacking 14 V Controller BUS 6 VC 5 03047 01 Baumüller Nürnberg Electronic GmbH Co KG ...
Страница 92: ...Parameter 90 V Controller BUS 6 VC 5 03047 01 Baumüller Nürnberg Electronic GmbH Co KG ...
Страница 108: ...Appendix 106 V Controller BUS 6 VC 5 03047 01 Baumüller Nürnberg Electronic GmbH Co KG ...
Страница 109: ......