Maintenance
V-Controller (BUS 6 VC)
95
Baumüller Nürnberg Electronic GmbH & Co. KG
5.03047.01
!
Function Module Processor Error Recognition (Error ID 0Cxx)
!
Function Module Power Unit continued (Error ID 0Dxx)
Error ID
Error Text
Meaning
Error reaction
Remedy
0B05
hex
Error in linking the pro-
gram modules
Inhibit pulses immedi-
ately
Test the RAM
0B06
hex
Error in the time seg-
ment system configura-
tion
0C01
hex
illegal external bus
access
Further information see
memory
0xFA00 up to
0xFA0F.
re-boot controller
0C02
hex
illegal instruction
access
0C03
hex
illegal word operand
access
0C04
hex
protection fault
0C05
hex
undefined opcode
0C06
hex
stack underflow
0C07
hex
stack overflow
0C08
hex
external non maskable
interrupt
0C09
hex
watchdog time-out
Error
identifi-
cation
Error text
Meaning
Error response
Disturbance elimination
0D01
hex
Short circuit of the tem-
perature sensor (power
unit)
Inhibit pulses immedi-
ately
Содержание BUS 6 VC
Страница 1: ...E 5 03047 01 Manual V Controller BUS 6 VC Specification Digital Control BUC ...
Страница 4: ...Dokument Nr Document No 5 04058 01 Baumüller Nürnberg GmbH ...
Страница 8: ...6 V Controller BUS 6 VC 5 03047 01 Baumüller Nürnberg Electronic GmbH Co KG ...
Страница 14: ...Technical Data 12 V Controller BUS 6 VC 5 03047 01 Baumüller Nürnberg Electronic GmbH Co KG ...
Страница 16: ...Transportation Unpacking 14 V Controller BUS 6 VC 5 03047 01 Baumüller Nürnberg Electronic GmbH Co KG ...
Страница 92: ...Parameter 90 V Controller BUS 6 VC 5 03047 01 Baumüller Nürnberg Electronic GmbH Co KG ...
Страница 108: ...Appendix 106 V Controller BUS 6 VC 5 03047 01 Baumüller Nürnberg Electronic GmbH Co KG ...
Страница 109: ......