Parameter
62
V-Controller (BUS 6 VC)
5.03047.01
Baumüller Nürnberg Electronic GmbH & Co. KG
Parameter description
P190
DSM
command
This command instructs the data set management to load, to save and to delete an existing
data set.
P191
DSM
state
P192
DSM
message
If a message occurs during the implementation of a command, it is displayed in this parame-
ter.
NOTE
This parameter is independent of the parameter M communication source (P126) always
changeable.
Command
Meaning
0
reset of data set management
The parameter P191 till P195 are set automatically to 0.
5
save data set from user memory to EEPROM
6
load data set from EEPROM to user memory
7
delete EEPROM data set
8
input password
Bit no.
Meaning
0 ... 2
000 : STOP
Data set management is ready for a command or for changing data
sets.
001 : RUN
Data set management is processing a command.
011 : STAND_BY Data set management has finished a command.
3
1 : An error has occurred in the data set management.
Error code see P124, M error code and P192, DSM message
4 ... 15
reserved
Bit no.
Meaning
0
1: undefined command
1
1: data set not available
2
1: wrong check sum
3
1: parameter not changeable
4
reserved
5
1: memory full
6
1: error in configuration list
7
1: undefined parameter format
Содержание BUS 6 VC
Страница 1: ...E 5 03047 01 Manual V Controller BUS 6 VC Specification Digital Control BUC ...
Страница 4: ...Dokument Nr Document No 5 04058 01 Baumüller Nürnberg GmbH ...
Страница 8: ...6 V Controller BUS 6 VC 5 03047 01 Baumüller Nürnberg Electronic GmbH Co KG ...
Страница 14: ...Technical Data 12 V Controller BUS 6 VC 5 03047 01 Baumüller Nürnberg Electronic GmbH Co KG ...
Страница 16: ...Transportation Unpacking 14 V Controller BUS 6 VC 5 03047 01 Baumüller Nürnberg Electronic GmbH Co KG ...
Страница 92: ...Parameter 90 V Controller BUS 6 VC 5 03047 01 Baumüller Nürnberg Electronic GmbH Co KG ...
Страница 108: ...Appendix 106 V Controller BUS 6 VC 5 03047 01 Baumüller Nürnberg Electronic GmbH Co KG ...
Страница 109: ......