Analog/Digital Interface
X26 SUB-D socket 25 pin
Buchse
Pin no.
Assignment
1
analog input 1, differential
2
analog input 1, differential signal -
3
analog input 2, differential
4
analog input 2, differential signal -
5
analog power supply, + 15 V
6
analog power supply, analog reference potential
7
analog output 1
8
analog output 2
9
must not be connected !
10
must not be connected !
11
bbo
relay break contact ready for use
12
bbk
relay changeover contact ready for use
13
bbs
relay make contact ready for use
14
pulse enabling (24 V)
15
digital input 1 (24 V)
(freely programmable)
16
digital input 2 (24 V)
(freely programmable)
17
digital input 3 (24 V)
(programmed with reset error)
18
digital input 4 (24 V)
(freely programmable)
19
must not be connected !
20
ground for digital inputs 1 to 4
21
digital output 1 (24 V)
(freely programmable)
22
digitaler output 2 (24 V)
(ready for pulse enabling)
23
digitaler output 3 (24 V
(main contactor on)
24
ground digital outputs 1 to 3
25
+24 V for digital inputs 1 to 4,
pulse enabling and
digital outputs 1 to 3
NOTE
A secure separation must be ensured externally.
Содержание BUS 6 VC
Страница 1: ...E 5 03047 01 Manual V Controller BUS 6 VC Specification Digital Control BUC ...
Страница 4: ...Dokument Nr Document No 5 04058 01 Baumüller Nürnberg GmbH ...
Страница 8: ...6 V Controller BUS 6 VC 5 03047 01 Baumüller Nürnberg Electronic GmbH Co KG ...
Страница 14: ...Technical Data 12 V Controller BUS 6 VC 5 03047 01 Baumüller Nürnberg Electronic GmbH Co KG ...
Страница 16: ...Transportation Unpacking 14 V Controller BUS 6 VC 5 03047 01 Baumüller Nürnberg Electronic GmbH Co KG ...
Страница 92: ...Parameter 90 V Controller BUS 6 VC 5 03047 01 Baumüller Nürnberg Electronic GmbH Co KG ...
Страница 108: ...Appendix 106 V Controller BUS 6 VC 5 03047 01 Baumüller Nürnberg Electronic GmbH Co KG ...
Страница 109: ......