Parameter
78
V-Controller (BUS 6 VC)
5.03047.01
Baumüller Nürnberg Electronic GmbH & Co. KG
7.14 Analog Outputs
Function
The module „analog outputs“ transmits freely selectable (and scalable) parameter values to an analog
output via a 12-bit digital-to-analog converter. It is possible transmitting 32-bit parameter either the low
word to one channel or to channel 1 the low word and to channel 2 the high word of the 32 bit parameter.
At a voltage range of
±
10 V the output current should not exceed 1 mA.
Parameter overview
NOTE
The following sequence must be observed for writing the parameters:
1. AA x
source-Pxxx
2. AA x
offset
3. AA x
scaling
Parameter
Name
Range
min. ... max.
Unit
Display
only
P338
AO
state
0 ... FFFF
-
!
P337
AO
test value
-10,000 ... +10,000
V
P330
AO
1 source Pxxx
0 ... 700
P331
AO
1 offset
-100000 ... +100000
Dig
P332
AO
1 scaling
-25000 ... +25000
Dig/V
P334
AO
2 source Pxxx
0 ... 700
P335
AO
2 offset
-100000 ... +100000
Dig
P336
AO
2 scaling
-25000 ... +25000
Dig/V
Содержание BUS 6 VC
Страница 1: ...E 5 03047 01 Manual V Controller BUS 6 VC Specification Digital Control BUC ...
Страница 4: ...Dokument Nr Document No 5 04058 01 Baumüller Nürnberg GmbH ...
Страница 8: ...6 V Controller BUS 6 VC 5 03047 01 Baumüller Nürnberg Electronic GmbH Co KG ...
Страница 14: ...Technical Data 12 V Controller BUS 6 VC 5 03047 01 Baumüller Nürnberg Electronic GmbH Co KG ...
Страница 16: ...Transportation Unpacking 14 V Controller BUS 6 VC 5 03047 01 Baumüller Nürnberg Electronic GmbH Co KG ...
Страница 92: ...Parameter 90 V Controller BUS 6 VC 5 03047 01 Baumüller Nürnberg Electronic GmbH Co KG ...
Страница 108: ...Appendix 106 V Controller BUS 6 VC 5 03047 01 Baumüller Nürnberg Electronic GmbH Co KG ...
Страница 109: ......