1.2 Reception of the appliance
Before accepting the machine, verify that all the data on the data-plate corresponds to the
required ones and to the ones of the available electrical supply (see paragr.
1.1 Dataplate
).
After removing the packing, ensure that the appliance has not been damaged in transport. If so,
do notify the seller immediately about the problem. If the damage might question the machine
safety, do not install it.
The installation and the starting of the machine must be carried out by trained operators only,
even if the machine is coming from another site and it has been used, already.
For disposal of the packing see paragr.
7.2 Disposal
.
1.3 Hydraulic connection
Connect the machine's water supply with an interrupt valve capable of quickly and completely shutting off water intake. Make
sure that the water supply pressure comes within the values given in the table Tab. 1. If it is less than 2 bar dynamic pressure
(200 kPa) a pressure pump
must be installed
to guarantee optimal machine operation (by request, the dishwasher can be
supplied with a pump). If, however, the water supply pressure is greater than 4 bar (400 kPa), a pressure reducing device
must
be installed
.
For water with average hardness greater than 8 °f, a water softener
must be used
. This will result in cleaner dishes and longer
life of the appliance. By request, the machine can be equipped with a water softener
If the machine is equipped with a water-softener, a regeneration of the resins shall be done on regular basis. In machines
equipped with optional
regeneration device
it is advisable to use water at a temperature not above 40 °C, so as not to alter the
characteristics of the resins.
Note
: Any damage caused by limestone (calcareous water higher-up than 8 °f and without water-softener) will not be covered
by warranty.
In order to ensure the optimum performance, the water supply temperature must come within the range given in table Tab. 1.
Machines shall be made with extra power in case of cold water infeed.
Each machine is provided with a rubber tube with a 3/4” threaded attachment for water filling.
Connect the emptying tube, supplied with the appliance, to the union elbow located under the tub so that water flows freely. If it
is not possible to empty the water at a level lower than the drain of the appliance, it is advisable to install an emptying pump,
which can be provided by request.
The emptying tube should always be connected to a siphon to prevent odor back-up from the screen.
Tab. 1
Water characteristics table
Min
Max
Static Pressure
200 kPa
400 kPa
Dynamic Pressure
150 kPa
350 kPa
Water hardness
2 °f
8 °f
Cold water-supply temperature
5 °C
50 °C
Hot water-supply temperature
50 °C
60 °C
Capacity
10 l/min
1.3.1 Water supply characteristics
The machine water supply must be potable, in compliance with the legislation in force.
The inlet water must also meet the parameters given in the table Tab. 1.
Tab. 2
Water parameters table
Min
Max
Chlorine
1
2
mg/l
pH
6,5
1
8,5
3
Water hardness
8 °f
2-3
Iron
3
0,2
mg/l
Manganese
4
0,05
mg/l
1
Out of range values might lead to corrosion and jeopardize the life of the machine.
2
Should the water hardness is higher
it is compulsory
to install a water softener and check periodically its operation.
3
Out of range values might lead scaling and sediments with a consequent lower performance, functionality, and expected life
of the machine.
4
4 Desired value: Out of range values might lead stainless steel blackening/tarnishing.
It is recommended a water test once a year.
page 8