4.5 Regeneration device (optional)
Should the machine be equipped with a water-softener circuit, this will be fully automatic. When needed, a 120” regeneration
cycle will automatically activate. During this phase, the regeneration indicator
F6
lights up.
If needed the cycle can be activated even during the wash-tank loading.
If the activation is made during the wash-cycle, this will be longer.
The circuit board is designed to call periodically for a 20 min. manual regeneration cycle (according with the water hardness
adjusted). The indicator
F6
flashes. This regeneration cycle can also be activated by the user, should the rinse quality be
dissatisfactory.
S
!
1
3
2
4
S
!
1
3
2
4
IMPORTANT:
Before starting a regeneration cycle check if there is salt in the special container.
When the
F8
indicator flashes on the display it means that the salt level in the bowl is low (only on
machines equipped with the optional Water Softener).
• To start the regeneration cycle, switch the machine OFF with the key
A
.
• Take off the overflow pipe. Drain the wash-tank.
• For machines equipped with drain pump see par.
4.4 Drain pump system (optional)
.
• Press
the
button
B
. The regeneration indicator
F6
lights up and the machine carries out with the various phases.
• The cycle is finished when the indicator
F6
goes off after around 20 minutes.
S
!
1
3
2
4
Note:
Regeneration times will be blocked only if the door is opened.
The optional regeneration is not allowed in the following conditions:
• During
programming.
• During the wash cycle.
• During manual draining.
• if the door is open; in this case the message
door
will be displayed for about 4 seconds.
• If the machine is ON.
In case of water hardness above 35 °f an external water softener is recommended.
page 17