BANLAW PRODUCT DATA SHEET
RESTRACK ADVANCED CONTROLLER
Doc ID: PRH-FMG-21 Version: 1.0
Page
6
of
20
Please ensure you have the latest version of this document.
Key Advantages of the Banlaw ResTrack
™
Controller:
•
Automatic identification of users, vehicles and plant equipment
•
Automatic recording of fluid deliveries and fluid dispensing
•
Accurate fluid metering with temperature compensation and bulk air elimination
•
Stainless steel cabinet, providing superior durability and corrosion resistance.
•
Compatible with HID and Cardax security card systems
•
The FTP (Fluid Transfer Points) provide, actuator control, iButton (Auto ID) read, RTD (Resistance
Temperature Detector) input (PT100 to PT1000), one channel pulse count inputs (with a count
comparison channel option), override and alarm Inputs.
•
Ethernet, 3G/4G, Wi-Fi connectivity options for VPN cloud or local communications and
configurable alarms and alerts by email.
The safe installation and subsequent operation of a Banlaw product rely on the completion
of all necessary
“due diligences”
for the assessment of the Banlaw product(s) being suitable
for the intended application(s). Such an assessment is best achieved through the mutual
cooperation of the supplier/OEM (Banlaw) and the customer or end-user. Once such an
assessment deems the Banlaw product(s) to be suitable, the customer or end-user shall
ensure effective
“change management”
applies should any prominent or influential aspect
of the application (upon which the initial assessment was based) be subject to change and
may affect the ongoing suitability (i.e. safety and proper function) of the Banlaw product.
The content of this document is not meant to override or substitute any applicable
Statutory, Regulatory, Customer/Site, etc. Health Safety and Environment (HS&E)
requirements.
All works should only be performed by trained, qualified and competent personnel who
are aware of the hazards associated with the constituent components of this installation
in addition to the system. Failure to comply with these practices may result in death,
serious bodily injury, loss of equipment and environmental damage.
A risk assessment (job hazard analysis - JHA) should be conducted PRIOR to the start of
any works or actions within this document. Whilst every effort has been made to ensure
the execution of this document represents no HS&E hazard, Banlaw takes neither
responsibility nor liability for the consequences and damages that may occur in the
execution of works within this document.
Persons conducting or otherwise involved with the execution of the works within this
document and project have an obligation to ensure that all HS&E requirements are
known and understood, and subsequently followed at all times.