5.5.12 Installing operating elements on the expansion cover
The following requirements must be met:
•
All connected cables must be disconnected.
•
The Automation Panel must no longer be installed on the VESA or swing arm system.
B&R recommends the following operating elements for proper installation and operation:
•
RAFIX 22 FS series
•
RAFIX 22 FS+ series
•
SHORTRON series
The corresponding manufacturer specifications must be observed when installing operating elements.
1. Disconnect the power supply cable to the device (disconnect the power cable!). Disconnect from all sources
and poles!
2. Carry out electrostatic discharge at the ground connection.
3. Place the Automation Panel on a clean, flat surface.
4. If an expansion unit is installed, it must first be removed. To do so, follow the instructions in section
the expansion unit/cover" on page 161
5. If an expansion cover is not installed, then one must be installed. To do so, follow the instructions in section
"Installing the expansion unit/cover" on page 163
Information:
The following steps can only be performed after an expansion cover has been installed in the
Automation Panel 5000.
6. Cut through the panel overlay from the inside with a sharp object (e.g. scalpel) along the outer edges of the
3 curved cutout areas.
7. Carefully cut the panel overlay at the notch for the anti-twist lock.
8. Cut through the panel overlay along the outer edges of the middle cutout with a scalpel.
9. Push though the cutout for the operating element with a flat-blade screwdriver.
10.Cut the panel overlay so that it is flush with the edge of the steel plate.
11.Operating elements can now be installed on the expansion cover.
For more information about operating and switching elements, see section
.