Technical data
Automation Panel 5000 User's manual V2.11
137
Model number
5ACCKP05.185B-000
5ACCKP05.215C-000
5ACCKP05.240C-000
Key switch
Quantity
1
Type
RAFIX 22 FS 1.30.255.222/0000
Contact element
Maintained
Emergency stop
Quantity
1
Type
RAFIX 22 FS+, Plus 1, 1.30.273.512/0300
Contact element
Maintained
Operating conditions
Pollution degree per EN 61131-2
Pollution degree 2
Mechanical properties
Material
Steel sheet
Weight
900 g
1000 g
1100 g
Table 66: 5ACCKP05.185B-000, 5ACCKP05.215C-000, 5ACCKP05.240C-000 - Technical data
4.2.5.5.4 B&R wireless assembly
B&R wireless assembly RFM-2-NF of 5ACCKP03.xxxx-000 or 5ACCK05.xxxx-000 expansion units consists of the
following wireless module:
•
SRD (RFID/NFC) module TWN4 MultiTech Nano from Elatec with circuit board antenna from B&R.
The B&R wireless assembly must be connected internally to the system using the USB 2.0 cable.
4.2.5.5.4.1 Drivers, software and documentation
Drivers, software tools and documentation for approved operating systems are available for download in the Down-
loads section of the B&R website (
). The software packages for the TWN4 MultiTech Nano
must be used.
4.2.5.5.5 USB interface
The expansion unit is equipped with a USB 2.0 interface. This is equipped with a protective cover.
Caution!
IP65 protection can only be achieved if the USB protective cover is properly installed.
Warning!
USB peripheral devices can be connected to the USB interfaces. Due to the variety of USB devices
available on the market, B&R cannot guarantee their functionality. The functionality of USB devices
available from B&R is guaranteed.
Caution!
Due to the general PC specification, this interface must be handled with the utmost care with regard
to EMC, cable routing, etc.
The USB interface is internally connected to the system via USB 2.0 and available to the user for service purposes.
Depending on the transfer method (SDL, DVI, SDL3 or SDL4 operation), there may be limitations with regard to the
transfer rate of the USB interfaces. For possible transfer methods, see section
"Connection options" on page 21
Transfer method
USB type
Max. cable length
SDL operation without USB cable
USB 1.1
25 m
1)
SDL operation with USB cable
USB 2.0
5 m
Single-touch DVI operation
USB 2.0
5 m
Multi-touch DVI operation
USB 2.0
5 m
SDL3 operation
USB 2.0
100 m
SDL4 operation
USB 2.0
100 m
1)
The max. cable length of 25 m depends on the resolution. For exact specifications, see table