Bandit
26
Copyright 1/18
MODEL 12XPC
Some Current
Engine Types
GM 3.0 - 89 Hp
GM 4.3 - 130 Hp
CAT C3.4 / Perkins 854F - 74 Hp
Cat C3.4 / Perkins 854F - 122.5 Hp
Kohler KDI2504 - 74 Hp
Maximum
RPM
2600
2600
2200
2200
2600
PPR
2
2
N/A
N/A
N/A
Off
RPM
2400
2400
2100
2150
2400
On
RPM
2150
2150
1750
1750
2000
Feed
Reverse Time
139 / .3
139 / .3
139 / .3
139 / .3
139 / .3
LOR Jumper Plug
Part No.: 900-2913-51
IEC Jumper Plug
Part No.: 900-2914-09
TROUBLE SHOOTING GUIDE cont.
Autofeeds with dump blocks can be unplugged and run manually. Autofeeds with dual output
block will need a jumper plug. This can be a good test to determine if you problem is hydraulic or electronic.
NOTICE
PROBLEM
POSSIBLE CAUSE
SOLUTION
Feedwheels Run
In Reverse From
Normal
-Backup time set wrong.
-Reset backup time. Normal setting is 180 milliseconds
(139 for Models 12XPC/12XP/15XP/95/990) (IEC) or
.3 seconds (LOR)
-Sticking reverse valve.
-Check solenoid operation.
-Override cartridge manually by sticking a small
allen wrench in the end of the solenoid.
-Replace solenoid and/or cartridge.
Type settings programmed
wrong.
-Reprogram or consult local dealer or Bandit Ind
APPROXIMATE DIGITAL AUTOFEED SETTINGS
(FOR ALL AUTOFEED SYSTEMS - REFERENCE ONLY)
Refer to the Completion/Check Sheet, that is shipped with the machine for the correct engine
rpm. If needed, contact your local dealer or Bandit Industries.
NOTICE
AUTOFEED OPTIONS
Содержание INTIMIDATOR 12XPC
Страница 19: ......
Страница 35: ...Bandit 21 Copyright 1 18 MODEL 12XPC DECALS...
Страница 36: ...Bandit 22 Copyright 1 18 MODEL 12XPC DECALS...
Страница 43: ...Bandit 27 Copyright 1 18 MODEL 12XPC LEFT RIGHT BACK FRONT CONTROLS MACHINE ORIENTATION REFERENCE...
Страница 128: ...Bandit 112 Copyright 1 18 MODEL 12XPC SERVICE RECORD SERVICE RECORD DATE DESCRIPTION AMOUNT...
Страница 153: ...BANDIT CONTROLS 25 245774458290 21Dec2016 Document notes 21Dec2016 First Draft...