BANDIT CONTROLS - CE
3/19
82
14
245840062970 8Oct2018
Push Button Feed Assist
Manual Winch with Push Button Feed Assist
There is a switch on the winch that sends a 12V signal to enable the winch valve. The winch stow switch
indicates to the control system whether the winch is stowed or deployed. The status of this switch is
displayed on Maint1 as shown above right.
When the Winch is deployed away from its stow point the Stow Switch energizes the winch selector valve and
now the winch can be operated using the manual winch control valve. While the winch is still out, the Feed
Assist Push Button can be used to enable Feed Fwd for approx 1/2 sec, then it will timeout and stop; this can
be repeated.
In order for the Feed Assist timer to work and allow oil during Feed Assist, the controller must see :
- a 4.99V (12V) signal from the Winch Out Switch
- a 10,000 (>500) signal from Fd Assist Switch
When the operator is finished with winch operations, the winch rope must be stowed properly to tighten
down on the Stow Bar. The Winch Out Switch will now indicate that the winch is no longer deployed and
normal chipper functions can resume feed fwd, etc.
The Yoke/Lift is disabled while winch is deployed. Except, Yoke/Lift can momentarily operate with Feed-
Assist-Fwd. Yoke/Lift is fully enabled again once the winch is properly stowed tight on the stow bar.
If the Feed Assist Switch is disconnected a 10,000 (>500) signal will be sent to the control system. The Feed
Assist will then time out and prevent Feeding until the switch is reconnected to ground for 0 (<500) signal.
Push Button Feed Assist Valve and Switch
Содержание Intimidator 12XP
Страница 2: ......
Страница 18: ......
Страница 80: ...66 3 19 Replacement Parts Model 12XP CE HYDRAULIC FUEL TANK ASSEMBLY 4 5 10 6 7 9 8 7 11 3 2 2 1...
Страница 82: ...68 3 19 Service Record Model 12XP CE SERVICE RECORD DATE DESCRIPTION AMOUNT...
Страница 106: ...Bandit Controls CE 3 19 92 24 245840062970 8Oct2018 Program Notes Thr dn btn overrides thr up input...
Страница 108: ...Bandit Controls CE 3 19 94 SERVICE RECORD DATE DESCRIPTION AMOUNT...