BANDIT CONTROLS - CE
3/19
80
12
245840062970 8Oct2018
Setup Page (Password protected)
1. Select down to the parameter you wish to adjust.
2. & 3. Increase or decrease the value of the selected parameter, or select through various options.
4. Go to Factory Settings (password protected).
5. Go back.
AutoFeed
During normal operation the feed system will reverse, stop, and resume based on the AutoFeed Engine Speed
settings. In the example screen shot above,
when Eng RPM falls below AutoFeed Lo 1800rpm,
the feed wheels will briefly reverse for AutoFeed Rev Time 450ms and then stop.
The system will wait for Eng RPM to recover above AutoFeed Hi 2100rpm
and then Feed Fwd will resume.
(Note: if AutoFeed Hi setting value is mistakenly set higher than the engine can run, the Feed system will not
Feed Fwd because it is waiting for the engine to reach a speed it cannot attain. Correct the AutoFeed Hi
setting to approx 100-200rpm lower than max engine speed).
1
2
3
4
5
Fuel Saver - Behind the FuelSave Load setting (48%
as shown) is the actual Load on the engine (38% as
shown). The setting is typically 10% higher than
actual load at high idle with clutch engaged.
In this case we would have seen approx 38%
engine load when clutch is engaged and engine at
full speed, no material being fed. And so 48% was
selected as the FuelSave Load setting; this assumes
that loads above 48% indicate material is being fed.
Содержание Intimidator 12XP
Страница 2: ......
Страница 18: ......
Страница 80: ...66 3 19 Replacement Parts Model 12XP CE HYDRAULIC FUEL TANK ASSEMBLY 4 5 10 6 7 9 8 7 11 3 2 2 1...
Страница 82: ...68 3 19 Service Record Model 12XP CE SERVICE RECORD DATE DESCRIPTION AMOUNT...
Страница 106: ...Bandit Controls CE 3 19 92 24 245840062970 8Oct2018 Program Notes Thr dn btn overrides thr up input...
Страница 108: ...Bandit Controls CE 3 19 94 SERVICE RECORD DATE DESCRIPTION AMOUNT...